Dynamic 31p Mrs of Exercising Human Muscle in a 7t Whole Body System, with Steam and Semi-laser Localisation

نویسندگان

  • M. Meyerspeer
  • E. Moser
چکیده

Introduction The purpose of this work is to examine the applicability of dynamic P MRS to a single exercising muscle using gradient based localisation in a 7T whole body scanner. The increased sensitivity obtainable with ultra high field is attractive for P MRS with its intrinsically low SNR. Dynamic studies of metabolism are often conducted using non-localised acquisitions using surface coils. Localising by single voxel spectroscopy has the potential of increasing specificity by limiting the VOI to e.g. a single exercising muscle, at the cost of SNR which may in turn necessitate temporal averaging, thus resulting in low temporal resolution. The challenges of dynamic MRS at ultra high field are susceptibility artifacts scaling proportionally with B0 (potentially annihilating the SNR benefit), particularly in the presence of motion during exercise, limits of RF power and excitatin bandwidth due to increased spectral dispersion. Subjects and Methods A healthy subject (female, 26 yrs, BMI = 18.7) performed plantar flexion exercise using a custom built ergometer [1] on two study days. Written informed consent to the protocol was obtainded in accordance to the regulations of the local ethics committee. Excitation and reception of RF signals was achieved using a dual tuned loop coil, 10 cm (Rapid Biomedical, D) interfaced to a Siemens 7T whole body MR scanner. For high order shimming the manufacturer's 3D shim was used. A double oblique voxel localised with STEAM and, alternatively, semi-LASER [2] with adiabatic refocusing, was placed in gastrocnemius muscle (Fig. 1), adjusted to the muscle's shape: VOI = 32 / 40 ml, TR = 8 s, TE = 17 / 53 ms, RF pulse durations: 3.4 ms / 10 ms, BW~2580 Hz. After 3 min of rest, aerobic plantar flexion exercise was performed for 5 min, inducing significant PCr depletion and intracellular pH shift (see results), subsequently, acquisitions of spectra contimued for 8.5 min, saving each FID separately. PCr was quantified from single acquisitions, 8 spectra were averaged for Pi quantification and pH calculation using AMARES. PCr amplitudes of recovery were fitted to an exponential function of PCr recovery rate constant, end exercise PCr depletion and equilibrium concentration. Results 90° pulses / adiabatic conditions were achieved in the volume of interest placed in the gastrocnemius muscle, at a distance of c. 3 cm from the plane of the coil. Most strikingly, the line width of the PCr was only 6-10 Hz at rest, 10-13 Hz during exercise, and 9-10 Hz after exercise. Narrow lines, high SNR and the absence of DC artifacts the quantification of spectra from single acquisitions, resulting in PCr recovery time courses from a single exercising muscle with a temporal resolution of 8 s (= TR). See Fig. 2 for a stack plot of spectra and fitted PCr exercise and recovery data. The muscle's average pH was 7.05 (rest), 6.73 (exercise), 7.1 (recovery). In the aerobic exercise bouts of similar intensity, that were studied with STEAM and semi-LASER, PCr was depleted by 54 ± 3 % and 59 ± 3 % with calculated half times of PCr recovery of 44 ± 6 s and 37 ± 4 s. Despite longer TE of semi-LASER, a c. 1.6 fold increase in PCr SNR compared to STEAM was observed in resting spectra acquired with otherwise equal parameters. Discussion and Conclusion We demonstrate that localised P MRS can be used to follow metabolic changes with 8s time resolution in a 7T whole body scanner, using STEAM and semi-LASER. The line width of PCr was comparable to previous results at 3T, indicating that the SNR benefit of the high field may be exploited and invested in spatial and temporal resolution, thereby increasing specificity. The band width of the excitation pulse resulted in a chemical shift artifact (% of VOI) for Pi, γ-, αand β-NTP of 23, 12, 35 and 75 %, which can be reduced by further RF pulse optimisation. The semi-LASER's long TE is a disadvantage for metabolites with short T2. While ISIS yields more signal, it lacks the advantage of a single shot sequence and requires 8 repetitions for 3D localisation. LASER based sequences can be advantageous for quantification of J-coupled resonances [3, 4], e.g. for ATP. References 1. Meyerspeer, M., et al. Magn Reson Mater Phy, 2005. 18(5):257. 2. Scheenen, T. W., et al. Magn Reson Mater Phy, 2008. 21(1-2):95. 3. Ouwerkerk. ISMRM 09, #1590, 4. Garwood, M. et al. J Magn Reson, 2001. 153(2):155. Fig. 1: Position of the VOI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semi-LASER localized dynamic 31P magnetic resonance spectroscopy in exercising muscle at ultra-high magnetic field

Magnetic resonance spectroscopy (MRS) can benefit from increased signal-to-noise ratio (SNR) of high magnetic fields. In this work, the SNR gain of dynamic 31P MRS at 7 T was invested in temporal and spatial resolution. Using conventional slice selective excitation combined with localization by adiabatic selective refocusing (semi-LASER) with short echo time (TE = 23 ms), phosphocreatine quanti...

متن کامل

Comparing localized and nonlocalized dynamic 31P magnetic resonance spectroscopy in exercising muscle at 7T

By improving spatial and anatomical specificity, localized spectroscopy can enhance the power and accuracy of the quantitative analysis of cellular metabolism and bioenergetics. Localized and nonlocalized dynamic (31)P magnetic resonance spectroscopy using a surface coil was compared during aerobic exercise and recovery of human calf muscle. For localization, a short echo time single-voxel magn...

متن کامل

Using a whole-body 31P birdcage transmit coil and 16-element receive array for human cardiac metabolic imaging at 7T

PURPOSE Cardiac phosphorus magnetic resonance spectroscopy (31P-MRS) provides unique insight into the mechanisms of heart failure. Yet, clinical applications have been hindered by the restricted sensitivity of the surface radiofrequency-coils normally used. These permit the analysis of spectra only from the interventricular septum, or large volumes of myocardium, which may not be meaningful in ...

متن کامل

In vivo 31P-MRS at 7T by single voxel E-ISIS with GOIA selection pulses

The GOIA-HS(8,4) pulses used for ISIS localisation offered excellent slice profiles with high bandwidth (20-40kHz) similar to FOCI but at lower B1 (Fig.2) or shorter pulses (~3 ms) even in 5 cm distance to the surface coil. Large selective gradients (25mT/m) reduced the CSDE to ±1.4mm for the most important metabolites (PME to γ-ATP) independent of voxel size. Contamination tests with TR~1.2T1 ...

متن کامل

Myocardial skeletal muscle signal spoiling using a crusher coil: a human cardiac phosphorus (31P) MR spectroscopic imaging study at 7 Tesla

Background P-MRS provides direct insights into myocardial energy supply (ATP, ADP, phosphocreatine (PCr) and inorganic phosphate). An initial study demonstrated that 7T cardiac P-MRS has 2.8x greater SNR than at 3T. However, the translation of more sophisticated P-MRS protocols to 7T is particularly challenged by increased RF heating of tissue at 7T. Chen and Ackerman introduced the surface spo...