Low-energy transvenous ablation of the canine atrioventricular conduction system with a suction electrode catheter.

نویسندگان

  • S Saksena
  • P P Tarjan
  • S Bharati
  • B Boveja
  • D Cohen
  • T Joubert
  • M Lev
چکیده

A single suction electrode catheter was used for His bundle electrogram recording. His bundle pacing, and low-energy (20 or 30 J) His bundle ablation in seven dogs. The suction electrode catheter was actively fixed to the atrial endocardium at the His bundle level. Electrophysiologic studies were performed in the control state, immediately after, and late (greater than 40 days) after His bundle ablation and results were correlated with histologic findings in the conduction system. Unipolar His bundle recording and pacing were successfully performed in all dogs with the suction electrode catheter before and after ablation. Complete heart block developed after a single 20 J shock delivered via the suction electrode catheter in all dogs immediately, but reverted to 1:1 atrioventricular conduction with first-degree atrioventricular block in two dogs in which one or two additional shocks (20 or 30 J) produced complete heart block. Mean ablation energy per shock was 22 +/- 4 J. The mean total delivered energy per dog was 31 +/- 20 J. Late electrophysiologic study in all dogs showed persistent complete heart block in five dogs and paroxysmal second-degree or third-degree atrioventricular block in two dogs. Gross examination of the ablation site showed a white plaque above the medial tricuspid leaflet (1.4 to 2.0 cm long and 0.4 to 0.6 cm wide). Microscopically, fibrosis of the penetrating and branching His bundle was seen in all dogs, with minimal atrioventricular node and atrial involvement. Significant proximal right bundle branch fibrosis was observed in the two dogs receiving one or two additional shocks. We conclude that the suction electrode catheter permits repeated His bundle recording, pacing, and ablation with a single catheter. Permanent and safe low-energy ablation of the canine His bundle is feasible. Focal injury localized to the target area in the conduction system can be obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transvenous ablation of atrioventricular conduction with a low energy power source.

A power source modified to increase voltage delivery and minimise arcing (for a given energy) was used for transvenous ablation of atrioventricular conduction to control refractory supraventricular arrhythmias in 14 patients. Twelve had atrial fibrillation or flutter, one had atrioventricular nodal reentry tachycardia, and the other had permanent junctional reentry tachycardia. Despite treatmen...

متن کامل

High frequency alternating current ablation of an accessory pathway in humans.

High frequency alternating current ablation of an accessory pathway was performed in a patient with incessant circus movement tachycardia using a right-sided, free wall accessory pathway. Antiarrhythmic drugs, antitachycardia pacing and transvenous catheter ablation using high energy direct current shocks could not control the supraventricular tachycardia. A 7F bipolar electrode catheter with a...

متن کامل

Transvenous catheter cryoablation of the atrioventricular node and visual assessment of freezing of cardiac tissue using intracardiac echocardiography.

We investigated the use of a catheter-based cryoablation system on atrioventricular (AV) junction ablation in dogs. In five dogs, the cryoablation catheter was introduced to the AV junction area in order to create transient high degree or complete AV block. Cryo-freezing energy was applied by lowering the temperature to -75 degrees C for five minutes as a single cycle. This cycle was repeated u...

متن کامل

Transvenous catheter ablation of extranodal accessory pathways.

Twelve patients with an accessory pathway and recurrent symptomatic reciprocating tachycardia or atrial fibrillation, or both, underwent attempted transvenous catheter ablation of the accessory pathway. In one patient with a small right coronary artery, the pathway was along the right free wall. In 11 patients, the pathway was located at or within 15 mm of the coronary sinus os. For these patie...

متن کامل

Catheter interruption of atrioventricular conduction using radiofrequency energy in a patient with transposition of the great arteries.

Percutaneous catheter mapping and radiofrequency ablation of the AV node-His bundle system (with subsequent transvenous endocardial ventricular pacing) were performed on an 18-year-old woman with transposition of the great arteries and intact ventricular septum and chronic arrhythmias 15 years following a Mustard operation. Exclusion of the AV conduction tissue from the systemic venous circulat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 76 2  شماره 

صفحات  -

تاریخ انتشار 1987