FDK-Type Algorithms with No Backprojection Weight for Circular and Helical Scan CT

نویسندگان

  • Adapa Venkata Narasimhadhan
  • Kasi Rajgopal
چکیده

We develop two Feldkamp-type reconstruction algorithms with no backprojection weight for circular and helical trajectory with planar detector geometry. Advances in solid-state electronic detector technologies lend importance to CT systems with the equispaced linear array, the planar (flat panel) detectors, and the corresponding algorithms. We derive two exact Hilbert filtered backprojection (FBP) reconstruction algorithms with no backprojection weight for 2D fan-beam equispace linear array detector geometry (complement of the equi-angular curved array detector). Based on these algorithms, the Feldkamp-type algorithms with no backprojection weight for 3D reconstruction are developed using the standard heuristic extension of the divergent beam FBP algorithm. The simulation results show that the axial intensity drop in the reconstructed image using the FDK algorithms with no backprojection weight with circular trajectory is similar to that obtained by using Hu's and T-FDK, algorithms. Further, we present efficient algorithms to reduce the axial intensity drop encountered in the standard FDK reconstructions in circular cone-beam CT. The proposed algorithms consist of mainly two steps: reconstruction of the object using FDK algorithm with no backprojection weight and estimation of the missing term. The efficient algorithms are compared with the FDK algorithm, Hu's algorithm, T-FDK, and Zhu et al.'s algorithm in terms of axial intensity drop and noise. Simulation shows that the efficient algorithms give similar performance in axial intensity drop as that of Zhu et al.'s algorithm while one of the efficient algorithms outperforms Zhu et al.'s algorithm in terms of computational complexity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Evaluation and Exploration of Measurement Uncertainty for Exact Helical Cone Beam Reconstruction Using Katsevich Filtered Backprojection in Comparison to Circular Feldkamp Reconstruction with Respect to Industrial CT Metrology

New requirements to scan long objects are fostering the use of helical scan trajectories. An exact filtered backprojection-based method has been suggested by Katsevich. In this paper, we investigate the applicability of this reconstruction strategy in industrial CT vs. conventional filtered backprojection type reconstructions. Hereby, we study the accuracy and the measurement uncertainty in ter...

متن کامل

Cone-Beam Reconstruction Using Filtered Backprojection

The art of medical computed tomography is constantly evolving and the last years have seen new ground breaking systems with multi-row detectors. These tomographs are able to increase both scanning speed and image quality compared to the single-row systems more commonly found in hospitals today. This thesis deals with three-dimensional image reconstruction algorithms to be used in future generat...

متن کامل

Exact and approximate algorithms for helical cone-beam CT.

This paper concerns image reconstruction for helical x-ray transmission tomography (CT) with multi-row detectors. We introduce two approximate cone-beam (CB) filtered-backprojection (FBP) algorithms of the Feldkamp type, obtained by extending to three dimensions (3D) two recently proposed exact FBP algorithms for 2D fan-beam reconstruction. The new algorithms are similar to the standard Feldkam...

متن کامل

A comparative study on interpolation methods for controlled cardiac CT

Bai et al. recently proposed to acquire random fanbeam/cone-beam projections with a linear/planar detector from a circular scanning locus for controlled cardiac computed tomography (CT). After specifying a uniform acquisition geometry required by FBP (filtration-backprojection), we rebin the random fan-beam/cone-beam data via nearest-neighbor, quadrilateral and triangle-based linear interpolati...

متن کامل

PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch.

Current applications of helical cone-beam computed tomography (CT) involve primarily a constant pitch where the translating speed of the table and the rotation speed of the source-detector remain constant. However, situations do exist where it may be more desirable to use a helical scan with a variable translating speed of the table, leading a variable pitch. One of such applications could aris...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012