Using milk flow rate to investigate milk ejection in the left and right breasts during simultaneous breast expression in women
نویسندگان
چکیده
BACKGROUND Milk ejection is essential for a successful lactation, however techniques to measure milk ejection in women are often complex and invasive. Recent research has demonstrated that at milk ejection, milk duct diameter increased in the breast (measured by ultrasound) at the same time as milk flow rate increased (measured using a weigh balance). This study aimed to evaluate a purpose-built continuous weigh balance (Showmilk, Medela AG) to measure changes in milk flow rate from the breast to identify milk ejections during milk expression. In addition, the Showmilk was used to determine if milk ejection occurred simultaneously in both breasts during double pumping. METHODS Increased milk flow rates during single pumping were compared to simultaneous ultrasound measurements of increased milk duct diameters in 14 mothers. In addition, increases in milk flow rate were compared between the left and right breasts of 28 mothers during double pumping for 15 minutes with two separate electric breast pumps attached to two Showmilks to record milk flow rate. RESULTS Increased milk flow rates were associated with increased milk duct diameters during single pumping. The mean number of milk ejections was not different between the Showmilk (4.2 +/- 2.0) and ultrasound (4.5 +/- 1.5) techniques. Overall, 67 milk ejections were measured and of these, 48 (72%) were identified by both techniques. The left and right breasts responded synchronously with 95.5% of the flow rate increases corresponding between the breasts. The mean number of milk ejections identified by an increase in milk flow rate during double pumping was 5.1 +/- 1.7 and 5.0 +/- 1.7 for the left and right breasts, respectively. In addition, mothers chose the same expression vacuum for the left (-198 +/- 31 mmHg) and right (193 +/- 33 mmHg) breasts. CONCLUSION The Showmilk can simply and non-invasively record milk ejections by measuring increases in milk flow rate that correspond with increases in milk duct diameter. For the first time measurement of milk flow rate has been used to confirm that milk ejections occur simultaneously in the left and right breasts during double pumping. The use of the Showmilk will facilitate further research into the relationship of milk ejection and milk removal.
منابع مشابه
Comparison of milk output from the right and left breasts during simultaneous pumping in mothers of very low birthweight infants.
PURPOSE Milk output from the right and left breasts was compared in mothers who were pumping exclusively and had not yet fed their infants at breast. METHODS Thirty-five mothers of very low birthweight infants established lactation with a hospital grade, electric, dual pump, and recorded milk output separately for each breast during every pumping session from enrollment until completion of th...
متن کاملAlcohol and Lactation
Background: Breastfeeding is the safest and best method for nurturing infant growth and health. While the harmful effects of alcohol during pregnancy are well-established, the consequences of alcohol intake during lactation have been far less examined. The effects of alcohol intake with large amounts noted on the infant include drowsiness, diaphoresis, deep sleep, weakness, decrease in linear g...
متن کاملHuman milk IgA concentrations during the first year of lactation.
AIMS To measure the concentrations of total IgA in the milk secreted by both breasts, throughout the first year of lactation, in a cohort of Gambian mothers of infants at high risk of infection. SUBJECTS AND METHODS Sixty five women and their infants were studied monthly from the 4th to 52nd postpartum week. Samples of milk were obtained from each breast by manual expression immediately befor...
متن کاملIn vivo assessment of number of milk duct orifices in lactating women and association with parameters in the mother and the infant
BACKGROUND In vitro and in vivo analyses differ between the number of milk ducts found in the lactating breast, and there is a lack of knowledge as to whether or not external factors in the mother or the child affect the number of ductal orifices. The aim of this study was to determine the number of milk duct orifices in vivo and to investigate the possible influence of variable parameters in m...
متن کاملMilk flow rates can be used to identify and investigate milk ejection in women expressing breast milk using an electric breast pump.
Currently there is no simple method available to assess milk ejection and breast milk flow in lactating women in both the clinical and research setting. The authors hypothesize that changes in milk flow rate are associated with milk ejection and therefore may provide a method suitable for the assessment of milk ejection and removal. Mothers (n = 23) expressed milk from one breast for a 15-minut...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International Breastfeeding Journal
دوره 4 شماره
صفحات -
تاریخ انتشار 2009