Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis
نویسندگان
چکیده
OBJECTIVES Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass. The objective of this study was to compare the PA values of normal individuals and their anthropometric measurements. MATERIALS AND METHODS Anthropometric measurements, Bioelectrical impedance analysis and PA measurements were done using Bodystat Quadscan 4000 machine on 42 healthy subjects between the age group of 18 to 50 yrs at a private hospital, Bangalore, Karnataka, India for eight months. Kolmogrov-Smirnov and Pearson's correlation tests were used for data analysis. RESULTS The PA values were 7.321.17º in healthy subjects. PA values were significantly positively correlated with body mass index (BMI) (r= 0.011, P<0.001). The phase angle values for males and females were 7.43±0.98º and 7.05±1.1.58º, respectively. CONCLUSION PA values positively correlated with BMI indicating the nutritional status of the study group. PA values were similar to the values to found in other studies.
منابع مشابه
Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis
Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...
متن کاملA bioelectrical impedance phase angle measuring system for assessment of nutritional status.
Bioelectrical impedance phase angle has been recommended as a tool to assess nutrition state, but there are no measuring devices have been specially designed for hospital residents. In this study, a system was established for the measurement of bioelectrical impedance phase angle. The electrical composition, calculation method and measuring method of this system are presented in this paper. Exp...
متن کاملOptimum electrode configuration for detection of leg movement using bio-impedance.
Impedances and joint angles were simultaneously measured during ankle and knee movements. The correlation coefficients of the joint angle and the impedance change from human leg movement were obtained using an electro-goniometer and a four-channel impedance measurement system. Because the impedance changes resulting from ankle and knee movements depended heavily on the electrode placement, we d...
متن کاملThe Application of Bioelectrical Impedance to Monitor Leg Movement
The purpose of this study is to provide a new approach for detection using bio-impedance. This impedance is measured by the four-electrode method. As the impedance changes resulting from ankle, knee, and hip movements depended heavily on electrode placement, we determined the optimal electrode configurations for those movements by searching for high correlation coefficients, large impedance cha...
متن کاملEvaluation of algorithms for calculating bioimpedance phase angle values from measured whole-body impedance modulus.
This paper addresses the problem of calculating the bioimpedance phase angle from measurements of impedance modulus. A complete impedance measurement was performed on altogether 20 healthy persons using a Solatron 1260/1294 system. The obtained impedance modulus (absolute impedance value) values were used to calculate the Cole parameters and from them the phase angles. In addition, the phase an...