Inaccuracies in Clinical Chemical Analysis
نویسنده
چکیده
Lithium and copper are distributed equally between cells and serum. However, red cells contain more magnesium, zinc, and iron than does serum. To assure analytical accuracy, hemolysis should be avoided. Also, cells and sera must be separated shortly after sample collection. Since aqueous solutions leach magnesium from glass containers, materials and reagents meant for magnesium analysis should be stored in plastic containers wasted to reduce trace nmeta] content. Specimens for zinc analysis are best collected and stored in washed plastic containers to avoid contamination by the zinc present in rubber stoppers of the usual evacuated tubes. Both flame and electrothermal atomization techniques can be applied to the analyses of these metals. Flame atomization is more practical for routine clinical determinations of lithium, magnesium, and zinc. Electrothermal atomization is preferred for copper and iron analyses. Background correction is essential for electrothermal atomization AAS.
منابع مشابه
Inquiry into Scientific Correctness of the Elementary School Farsi Textbooks
Inquiry into Scientific Correctness of the Elementary School Farsi Textbooks H. Ghamari, Ph.D.* Scientific validity or correctness is of paramount importance when it comes to the contents of textbooks used in elementary schools, as the very foundations of learners’ knowledge is constructed therein. Hence, an analysis of these contents from this perspective is necessary in order to guide...
متن کاملCertifying the cause of death: an audit of wording inaccuracies.
AIMS To audit wording and formulation inaccuracies in certifying the cause of death. METHODS Five hundred causes of death were analysed from the counterfoils of medical death certificates (Form 66). Wording and formulation inaccuracies were defined as terms contrary to the notes given to doctors in books on death certificates. RESULTS One or more inaccuracies were identified in 29% of cases...
متن کاملError Measurement for a Portable Tonometer
Most patients with glaucoma exhibit elevated intraocular pressure (IOP). A cost effective device that allows the patient to measure IOP at regular intervals may reduce vision loss. This research tested the Bausch & Lomb Proview self tonometer against a calibrated force meter. It further compared the Proview tonometer with results from the clinical gold standard, the Goldmann tonometer. Results ...
متن کاملMaximum Inaccuracies of Second Order
Let an indirectly measurable variable Y be represented as a function of finite number of directly measurable variables X1, X2, ..., Xn. We introduce maximum absolute and relative inaccuracies of second order of Y – this idea is a continuation of our research of a new principle for representing the maximum inaccuracies of Y using the inaccuracies of X1, X2, ..., Xn. Using inaccuracies of second ...
متن کاملPreanalytical aspects and sample quality assessment in metabolomics studies of human blood.
BACKGROUND Metabolomics is a powerful tool that is increasingly used in clinical research. Although excellent sample quality is essential, it can easily be compromised by undetected preanalytical errors. We set out to identify critical preanalytical steps and biomarkers that reflect preanalytical inaccuracies. METHODS We systematically investigated the effects of preanalytical variables (bloo...
متن کامل