New Scheme of Two Beam Accelerator Driver Based on Linear Induction Accelerator

نویسندگان

  • A. V. Elzhov
  • A. A. Kaminsky
  • A. K. Kaminsky
  • V. I. Kazacha
  • E. A. Perelstein
  • S. N. Sedykh
  • A. P. Sergeev
چکیده

A new scheme of two beam accelerator (TBA) driver based on a linear induction accelerator is suggested in this work The electron beam bunching occurs at a rather low initial energy ~1 MeV. The bunched beam is accelerated in the .accompanying enhanced synchronous microwave that provides the steady longitudinal beam bunching along the whole driver. There is no total microwave power extraction anywhere in the driver. A beam-loaded waveguide (initially corrugated and regular further) is used along the driver. The planned test experiment based on JINR LIA-3000 should yield the possibility of studying the bunching, microwave generation, beam propagation and twofold microwave extraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Medium-Term Stability of the Photon Beam Energy of An Elekta CompactTM Linear Accelerator Based on Daily Measurements of Beam Quality Factor

Introduction In this study, we aimed to assess the medium-term energy stability of a 6MV Elekta CompactTM linear accelerator. To the best of our knowledge, this is the first published article to evaluate this linear accelerator in terms of energy stability. As well as investigating the stability of the linear accelerator energy over a period of several weeks, the results will be useful for esti...

متن کامل

Protective and dosimeter design of the stationary and mobile model truck inspection system with electron linear accelerator radiation source

In this work, calculations of leaked dose from vehicle inspection area, the absorbed dose by driver and operator, and the required concrete thickness for shielding the inspection area are presented using the Monte Carlo code MCNPX2.6. The X-ray source of the present vehicle inspection system is a LinatronMi6 accelerator, end of which has only been simulated in this study (the electron beam coll...

متن کامل

Beam Dynamics Experiments in Support of Relativistic Klystrons*

Experiments to study beam dynamics for Relativistic Klystrons (RK) are being performed with a 1-MeV, 600-A induction accelerator beam. The RK is a RF Power source based on induction accelerator technology and conventional resonant output structures. Capable of generating 100's of MW/m at frequencies up to K-band, the RK has been proposed as a driver for a future linear collider in one version o...

متن کامل

محاسبه میزان دز پرتوهای ترمزی ناشی از الکترون ها در پرتو درمانی با الکترون در بیمارستان آیت ا...خوانساری اراک

During the radiation therapy with electron beam, due to electron interaction and scattering from structures of the head of the medical linear accelerator, unwanted photons are produced. The main contribution of the photon contamination is resulted from the various components of the medical linear accelerator on the way of the high energy electron beam, and few percent is due to the interaction ...

متن کامل

The Two-Beam Funneling Experiment

New high current accelerator facilities like proposed for the HIDIF driver require a beam with such a high brilliance, which can not be produced by a single pass rf-linac. The increase in brightness in such a driver linac is done by several funneling stages at low energies, in which two identically bunched ion beams are combined to a single beam with twice the frequency, current and brightness....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998