Sparsely sampled MR navigators as a practical tool for quality control and correction of head motion in simultaneous PET/MR
نویسندگان
چکیده
Dept. of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet (Copenhagen University Hospital), Denmark We present a study using MR navigators sampled between other protocolled MR sequences during PET/MR brain scanning, to make motion-QC and motion correction (MC) feasible in clinical simultaneous PET/MR, obviating the need for special MR sequences with interleaved (dense) navigators. During 30 min [11C]-PiB (453±148 MBq) PET listmode scans of 29 patients on the Siemens mMR, a set of 10 3D navigator volumes was acquired (2D EPI 3.0x3.0x3.0 mm voxels, 64x64 matrix, 36 slices, TE 30 ms, TR 3,000 ms) in between other scheduled MR acquisitions at 6 time points. The rigid motion between navigators was calculated (all motions given are for a point in the cortex 6 cm from the scanners cFOV). The 3 patients with largest motion (11, 8 and 8 mm) and the only 2 PiB-positive patients with motion > 4 mm (8 and 6 mm motion) were reconstructed into 6 frames with frames being split at the midpoint between navigator start times (framing [mean ±SD]: 259±8, 306±8, 191±2, 342±2, 546±1, 157±19 seconds) and then averaged to one image after MC. A blinded evaluation comparing non-MC and MC PiB images was performed by a nuclear medicine physician. The average maximum motion magnitude was 3.9±2.4 mm (1 to 11 mm). The visual evaluation of the 5 MC patients rated 3/5 non-MC images blurred (average score: 3.4±0.5 on a scale of 1-5) and 0/5 MC images blurred (score: 4.0±0.0) with no correlation between motion magnitude and rating. A slight, overall decrease in blurring and an increase in image quality rating with MC was found, but with no impact on clinical outcome. The effect of MC is limited with PiB, but with other tracers (e.g. FDG), longer scans, smaller ROIs or larger motion magnitudes, navigators are easily used for motion-QC and MC in clinical practice.
منابع مشابه
Motion correction in simultaneous PET/MR brain imaging using sparsely sampled MR navigators: a clinically feasible tool
BACKGROUND We present a study performing motion correction (MC) of PET using MR navigators sampled between other protocolled MR sequences during simultaneous PET/MR brain scanning with the purpose of evaluating its clinical feasibility and the potential improvement of image quality. FINDINGS Twenty-nine human subjects had a 30-min [(11)C]-PiB PET scan with simultaneous MR including 3D navigat...
متن کاملErratum to: Motion correction in simultaneous PET/MR brain imaging using sparsely sampled MR navigators: a clinically feasible tool
Erratum Unfortunately, the original version of this article [1] contained an error. The additional file contained citation errors. The link to the correct additional file can be found below. Additional file 1: Part 1: dependency of image noise properties on frame length. Part 2: individual motion components for the two example patients in Fig. 3. A, et al. Motion correction in simultaneous PET/...
متن کاملTowards Lissajous navigator-based motion correction for MR-PET
Introduction With the combination of Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) into a single combined system, a novel imaging modality has become available. Exciting new study designs investigating different aspects of the exact same biochemical process are finally possible thanks to simultaneous MRI and PET acquisition. Due to long acquisition times of up to hours...
متن کاملComparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملMR-Based PET Motion Correction Procedure for Simultaneous MR-PET Neuroimaging of Human Brain
Positron Emission Tomography (PET) images are prone to motion artefacts due to the long acquisition time of PET measurements. Recently, simultaneous magnetic resonance imaging (MRI) and PET have become available in the first generation of Hybrid MR-PET scanners. In this work, the elimination of artefacts due to head motion in PET neuroimages is achieved by a new approach utilising MR-based moti...