Breakthrough time of a respirator cartridge for carbon tetrachloride vapor flow of workers' respiratory patterns.

نویسندگان

  • S Tanaka
  • M Tanaka
  • K Kimura
  • K Nozaki
  • Y Seki
چکیده

Breakthrough times of a commercially-available respirator cartridge packed with a small amount of activated carbon were determined by three different flow patterns: workers' respiratory patterns, conventional steady-state flows, and three standard patterns consisting of rectangle, sine, and triangle waves. A mechanical breathing simulator was used to reproduce the three standard wave patterns as well as the workers' respiratory patterns, which had been recorded from three workers of a paint manufacturing plant wearing a gas mask equipped with a respirator cartridge. The breakthrough test was carried out with 300 ppm carbon tetrachloride vapor at average flow rates of the respiratory and standard patterns equivalent to the steady-state flow rates. The breakthrough times determined by the workers' respiratory patterns were found to be shorter than those by a steady-state flow of the equivalent flow rate, and to be as short as those by sine and triangle wave patterns. It was considered that shorter breakthrough times in the workers' respiratory patterns could be attributed to a faster maximum inspiratory flow rate than that in the case of steady-state flow. The present results suggest that the passing time of CCl4 molecules through the thin activated carbon layer of respirator cartridge may be too short to attain an adsorption equilibrium.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

 EN 14387:2004 کارایی انواع کارتریج های ماسک های تنفسی ویژه بخارهای آلی بر مبنای استاندارد

Background and Aim: Determining the degree of conformity of respirator cartridges with the accepted standards is very important for ensuring their respiratory protection efficiency. The aim of this study was to determine the degree of conformity of organic vapor-respirator cartridges used in different petrochemical companies with the EN 14387:2004 standard. Materials and Methods: In the first ...

متن کامل

Carbon tetrachloride replacement compounds for organic vapor air-purifying respirator cartridge and activated carbon testing--a review.

This article reviews efforts by researchers and organizations around the world to identify chemicals as substitutes for carbon tetrachloride in measuring activated carbon activity (adsorption capacity) or organic vapor air-purifying respirator cartridge (or other packed carbon bed) breakthrough times. Such measurements usually are done to determine if a minimum performance standard is met. Diff...

متن کامل

Investigation of hydrogen sulfide adsorption in metallic scaffold MOF-5 nanocomposite based on activated carbon for the use of respiratory mask cartridge

Introduction: Hydrogen sulfide is one of the most important impurities in natural gas. Due to the fact that this gas is hazardous, toxic, corrosive and volatile, therefore, the removal of hydrogen sulfide has been studied using several methods. One of the most known procedures is the adsorption process. In the present study, activated carbon and activated carbon-based composite scaffolds (MOF-5...

متن کامل

Evaluation of a passive optical based end of service life indicator (ESLI) for organic vapor respirator cartridges

A passive visual end of service life indicator (ESLI) for certain organic vapors has been attached to the inside wall of an organic vapor respirator cartridge. The opposite side of the ESLI touches activated carbon inside the cartridge. During use, organic vapors moving through the cartridge adsorb into both the carbon and the ESLI. The cartridge body is clear so that when vapor concentrations ...

متن کامل

Cyclohexane as an alternative vapor of carbon tetrachloride for the assessment of gas removing capacities of gas masks.

An alternative vapor was explored to replace carbon tetrachloride (CCl4) for testing breakthrough times of cartridges and canisters of gas masks in the National Approval Test of Respirators. Cyclohexane was single out as a candidate for the alternative vapor out of six vapors: trichloroethylene, n-pentane, n-hexane, n-heptane, toluene and cyclohexane from the viewpoints of similarity of vapor p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Industrial health

دوره 34 3  شماره 

صفحات  -

تاریخ انتشار 1996