Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel.

نویسندگان

  • Luca Testarelli
  • Gianluca Plotino
  • Dina Al-Sudani
  • Valentina Vincenzi
  • Alessio Giansiracusa
  • Nicola M Grande
  • Gianluca Gambarini
چکیده

INTRODUCTION The aim of the present study was to evaluate the bending properties of Hyflex instruments, which exhibit a lower percent in weight of nickel (52 Ni %wt) and compare them with other commercially available nickel-titanium (NiTi) rotary instruments. METHODS Ten instruments with tip size 25, 0.06 taper of each of the following NiTi rotary instrumentation techniques were selected for the study: Hyflex, EndoSequence, ProFile, Hero, and Flexmasters. All instruments from each group were tested for stiffness by comparing their bending moment when they attained a 45-degree bend. Experimental procedures strictly followed testing methodology described in ISO 3630-1. All data were recorded and subjected to statistical evaluation by using analysis of variance test. Statistical significance was set at P < .05). RESULTS Statistical analysis of the data revealed that Hyflex files were found to be the most flexible instruments, with a significant difference (P < .05) in comparison with the other instruments. Among the other files, a significant difference has been reported for EndoSequence instruments compared with ProFile, Hero, and FlexMaster (P < .05), whereas no significant differences have been reported among those 3 files (P > .05). CONCLUSIONS Results of the present study have illustrated an increased flexibility of the new NiTi alloy over conventional NiTi alloy, and they highlight the potential of the new manufacturing process.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical Properties of Copper-Nickel-Titanium Archwires

MECHANICAL PROPERTIES OF COPPER-NICKEL-TITANIUM ORTHODONTIC WIRES Margaret Rosen, D.M.D. Marquette University, 2016 Introduction: The initial phase of orthodontic therapy relies on flexible wires, usually composed of a nickel-titanium alloy, to apply a substantially constant load during tooth movement. Copper has been added to nickel-titanium archwires, resulting in an alloy with potential clin...

متن کامل

Optimization of the Pulsed Gas Tungsten Arc Welding in Dissimilar Joining Austenitic Stainless Steel AISI 316L to Nickel-Base Super Alloy of Monel 400

In this research, optimization of the pulsed gas tungsten arc welding including pulse current, background current, pulse frequency and on time were investigated in welding of non-similar materials of austenitic stainless steel AISI 316L and nickel-base super alloy of Monel 400 by using ERNiCr3 filler metal. In order to obtain optimum conditions of welding the Taguchi method with the L9 array wa...

متن کامل

Nickel-Titanium Alloys: Corrosion “Proof” Alloys for Space Bearing, Components and Mechanism Applications

An intermetallic nickel-titanium alloy, 60NiTi (60wt%Ni, 40wt%Ti), is shown to be a promising candidate tribological material for space mechanisms. 60NiTi offers a broad combination of physical properties that make it unique among bearing materials. 60NiTi is hard, electrically conductive, highly corrosion resistant, readily machined prior to final heat treatment, and is non-magnetic. Despite i...

متن کامل

Effect of dry cryogenic treatment on Vickers hardness and wear resistance of new martensitic shape memory nickel-titanium alloy

OBJECTIVES The aim of this study is to investigate the role of dry cryogenic treatment (CT) temperature and time on the Vickers hardness and wear resistance of new martensitic shape memory (SM) nickel-titanium (NiTi) alloy. The null hypothesis tested was that there is no difference in Vickers hardness and wear resistance between SM NiTi alloys following CT under two soaking temperatures and tim...

متن کامل

Endodontic rotary nickel-titanium instrument systems.PDF

Since the end of the nineteenth century, automated root canal instrumentation has been available, but systems had many problems. The challenges of increased canal blockage, instrument breakage, and insufficient canal debridement were related to the use of stainless steel instruments and have been dramatically improved with the introduction of nickel-titanium (NiTi) files. The first useable NiTi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 37 9  شماره 

صفحات  -

تاریخ انتشار 2011