a multi objective genetic algorithm (moga) for optimizing thermal and electrical distribution in tumor ablation by irreversible electroporation

نویسندگان

a. nickfarjam tarbiat modares university, medical physics department, tehran, iran.

s. m. p. firoozabadi tarbiat modares university, medical physics department, tehran, iran.

b. kalaghchi cancer research center, tehran university of medical sciences, tehran, iran.

چکیده

background: irreversible electroporation (ire) is a novel tumor ablation technique. ire is associated with high electrical fields and is often reported in conjunction with thermal damage caused by joule heating. for good response to surgery it is crucial to produce minimum thermal damage in both tumoral and healthy tissues named non-thermal irreversible electroporation(ntire). non-thermal irreversible electroporation attempts have concentrated on tumor ablation with strong electric field with producing minimum thermal damage. objective: to establish a multi objective genetic algorithm (moga) for ire treatment planning. methods: numerical modeling and genetic programming were coupled to optimize thermal and electrical distribution in tissue. a 3d mri based model was established and treatment parameters such as electrode thickness, electrode insertion, distance between electrode and applied voltage were optimized. results: prefect tumor ablation with ire surgery with relatively little electrical and thermal damage on healthy tissue can be achieved by using genetic algorithm optimization. such optimization can trade off between perfect tumor coverage and damage to healthy tissue. concerning the thermal aspect of ire surgery. conclusion: the established multi-objective genetic algorithm based treatment planning system, can optimize both geometric and electric parameters in ire surgery. such optimization result in prefect tumor ablation as well as minimum thermal damage to both normal and tumoral tissue.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Multi Objective Genetic Algorithm (MOGA) for Optimizing Thermal and Electrical Distribution in Tumor Ablation by Irreversible Electroporation

Background: Irreversible electroporation (IRE) is a novel tumor ablation technique. IRE is associated with high electrical fields and is often reported in conjunction with thermal damage caused by Joule heating. For good response to surgery it is crucial to produce minimum thermal damage in both tumoral and healthy tissues named Non-Thermal Irreversible Electroporation(NTIRE). Non-thermal irrev...

متن کامل

Tumor Ablation with Irreversible Electroporation

We report the first successful use of irreversible electroporation for the minimally invasive treatment of aggressive cutaneous tumors implanted in mice. Irreversible electroporation is a newly developed non-thermal tissue ablation technique in which certain short duration electrical fields are used to permanently permeabilize the cell membrane, presumably through the formation of nanoscale def...

متن کامل

A multi-objective genetic algorithm (MOGA) for hybrid flow shop scheduling problem with assembly operation

Scheduling for a two-stage production system is one of the most common problems in production management. In this production system, a number of products are produced and each product is assembled from a set of parts. The parts are produced in the first stage that is a fabrication stage and then they are assembled in the second stage that usually is an assembly stage. In this article, the first...

متن کامل

Tissue heating during tumor ablation with irreversible electroporation

Exposing biological cells to sufficiently strong external electric fields causes electroporation of cell membranes, i.e. occurrence of transient or permanent permeable pathways between the interior and exterior of the cell. Electroporation can be used to introduce various molecules into cells (reversible electroporation) or to kill cells (irreversible electroporation), which can in turn be used...

متن کامل

Immunologic Response to Tumor Ablation with Irreversible Electroporation

BACKGROUND Irreversible electroporation (IRE) is a promising technique for the focal treatment of pathologic tissues, which involves placing minimally invasive electrodes within the targeted region. However, the knowledge about the therapeutic efficacy and immune reactions in response to IRE remains in its infancy. METHODS In this work, to detect whether tumor ablation with IRE could trigger ...

متن کامل

Prediction of mechanical and fresh properties of self-consolidating concrete (SCC) using multi-objective genetic algorithm (MOGA)

Compressive strength and concrete slump are the most important required parameters for design, depending on many factors such as concrete mix design, concrete material, experimental cases, tester skills, experimental errors etc. Since many of these factors are unknown, and no specific and relatively accurate formulation can be found for strength and slump, therefore, the concrete properties ca...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of biomedical physics and engineering

جلد ۳، شماره ۱ Mar، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023