determination of trace copper(ii) in food samples by flame atomic absorption spectrometry after cloud point extraction
نویسندگان
چکیده
a new method for the determination of trace copper(ii) in food samples by cloud point extraction(cpe) combined with flame atomic absorption spectrometry(faas) is presented and evaluated. the method is based on the fact that hydrophobic complex of copper(ii) with sodium diethyldithiocarbamate (ddtc) was formed at ph 6.0 and subsequently the hydrophobic complex was extracted into surfactant-rich phase. copper(ii) in surfactant-rich phase was analyzed by faas after dilution the surfactant-rich phase to 0.5 ml by nitric acid in methanol(0.1 mol l-1). the main factors affecting cpe, such as ph, concentration of ddtc and triton x-114, equilibrium temperature and incubation time, sample volume were investigated in detail. the effect of coexisting ions on the recovery of copper(ii) was also investigated. under the optimum conditions, the detection limit(3σ) of this method was 1.1 ng ml-1 for copper(ii), and the relative standard deviation was 3.4 % (c=100 ng ml-1, n=7). the analytical results for the certified reference tea sample(gbw07605) were in a good agreement with the certified value. the proposed method was successfully applied to determination of trace copper(ii) in milk powder and mineral water with satisfactory results.
منابع مشابه
Determination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry after Cloud Point Extraction
A new method for the determination of trace copper(II) in food samples by Cloud Point Extraction(CPE) combined with Flame Atomic Absorption Spectrometry(FAAS) is presented and evaluated. The method is based on the fact that hydrophobic complex of copper(II) with sodium diethyldithiocarbamate (DDTC) was formed at pH 6.0 and subsequently the hydrophobic complex was extracted into surfactant-r...
متن کاملDetermination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination
Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...
متن کاملDetermination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry After Cloud Point Extraction
A new method for the determination of trace copper(II) in food samples by Cloud Point Extraction(CPE) combined with Flame Atomic Absorption Spectrometry(FAAS) is presented and evaluated. The method is based on the fact that hydrophobic complex of copper(II) with sodium diethyldithiocarbamate (DDTC) was formed at pH 6.0 and subsequently the hydrophobic complex was extracted into surfactant-rich ...
متن کاملdetermination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination
pb and cd in water samples were determined by cloud point extraction (cpe) with sodiumdiethyldithiocarbamate (ddtc) as the chelating agent and octylphenoxypolyethanl (triton x-114) asthe surfactant prior to flame atomic absorption spectrometry (faas) determination. the main factorsof affecting the extraction and detection processes were optimized. the preconcentration of 10 ml ofstandard soluti...
متن کاملDetermination of Trace Amount of Zn2+ Ion in soil, blood and vegetable and water samples by Flame Atomic Absorption Spectrometry After Cloud Point Extraction Using Selective Synthesis Ligand2-(3- indolyl) – 4,5 di phynyl imidazole.
Abstract A simple, sensitive and feasible cloud-point extraction (CPE) methodology has been developed for the separation and preconcentration of cadmium and lead ions in real samples. The metals in the aqueous solution were complexes with 2-(3- indolyl) - 4,5 di phynyl imidazole.(IDPI), at pH = 7.0 and Triton X-114 was added as surfactant. The variables effecting like concentration of Triton ...
متن کاملCloud Point Extraction of Trace Amounts of Copper and Its Determination by Flow Injection Flame Atomic Absorption Spectrometry
A simple and convenient method based on cloud point extraction was proposed for the determination of copper. The extraction was carried out in the presence of 2-[(2-mercaptophenylimino)methyl]phenol (MPMP) as the chelating ligand and octylphenoxypolyethoxyethanol (Triton X-114) as the non-ionic surfactant. After phase separation, the surfactant rich phase containing the complex was diluted with...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of chemistry and chemical engineering (ijcce)ناشر: iranian institute of research and development in chemical industries (irdci)-acecr
ISSN 1021-9986
دوره 30
شماره 3 2011
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023