trace amounts determination of vanadium (v) using a new kinetic-catalytic reaction system

نویسندگان

m. r. shishehbore

r. jokar

h. dashti khavidaki

چکیده

this study describes a new simple, sensitive and selective catalytic kinetic spectrophotometricmethod for the determination of vanadium (v). the method is based upon the catalytic effect ofvanadium (v) on the oxidation of carminic acid by bromate in sulfuric acid media. the reaction wasfollowed spectrophotometrically by measuring the decrease in absorbance at 490 nm and thedependence of sensitivity on the effective reaction variables was studied. under optimumexperimental conditions, the fixed time procedure was used to obtain a calibration curve over therange of 0.05–10.8 μg ml-1of vanadium (v). the calculated detection limit was 0.015 μg ml-1 fortwelve replicate measurement of blank signal. the relative standard deviations (n = 6) were 1.12,0.98% for 2.0, 8.0 μg ml-1 of vanadium (v), respectively. the effect of various species commonlyassociated with vanadium (v) in real samples was also investigated. the proposed method wassuccessfully applied for the determination of vanadium (v) in water and standard alloy samples.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trace Amounts Determination of Vanadium (V) Using a New Kinetic-Catalytic Reaction System

This study describes a new simple, sensitive and selective catalytic kinetic spectrophotometricmethod for the determination of vanadium (V). The method is based upon the catalytic effect ofvanadium (V) on the oxidation of Carminic acid by bromate in sulfuric acid media. The reaction wasfollowed spectrophotometrically by measuring the decrease in absorbance at 490 nm and thedependence of sensiti...

متن کامل

Kinetic-spectrophotometric determination of trace amounts of vanadium.

A simple and sensitive kinetic-spectrophotometric method is described for the determination of vanadium and the possible mechanism of catalytic reaction is proposed. The method is based on the vanadium(V)-catalyzed oxidation of 1,8-diaminonaphthalene (DNA) by potassium bromate (Tiron as activator) at pH 3.8 and 40 degrees C. The reaction was monitored spectrophotometrically by measuring the inc...

متن کامل

Sub-ppm determination of uric acid using a sensitive kinetic-catalytic reaction system

A sensitive and selective kinetic-spectrophotometric method was developed for the determination of trace amounts of uric acid. The method is based on the inhibitory effect of uric acid on the oxidation of Janus Green by bromate in the presence of sulfuric acid. The reaction was followed spectrophotometrically by measuring the absorbance at 518 nm using the fixed-time method. Under optimum exper...

متن کامل

KINETIC-SPECTROPHOTOMETRIC DETERMINATION OF TRACE AMOUNTS OF NITRITE BY THE REACTION OF METHYL ORANGE FORMATION

The composite diazotization coupling reaction of sulfanilic acid and N, Ndimethylaniline was used for the precise, accurate, and rapid determination of trace amounts of nitrite ion (0.02-3 µg/ml). The reaction was monitored spectrophotometrically by measuring the absorbance of the produced methyl orange at 510 nm by a fixed the method of 5.0 minutes. The relative standard deviation for the...

متن کامل

sub-ppm determination of uric acid using a sensitive kinetic-catalytic reaction system

a sensitive and selective kinetic-spectrophotometric method was developed for the determination of trace amounts of uric acid. the method is based on the inhibitory effect of uric acid on the oxidation of janus green by bromate in the presence of sulfuric acid. the reaction was followed spectrophotometrically by measuring the absorbance at 518 nm using the fixed-time method. under optimum exper...

متن کامل

kinetic-spectrophotometric determination of trace amounts of nitrite by the reaction of methyl orange formation

the composite diazotization coupling reaction of sulfanilic acid and n, ndimethylaniline was used for the precise, accurate, and rapid determination of trace amounts of nitrite ion (0.02-3 µg/ml). the reaction was monitored spectrophotometrically by measuring the absorbance of the produced methyl orange at 510 nm by a fixed the method of 5.0 minutes. the relative standard deviation for the dete...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of physical & theoretical chemistry

ISSN

دوره 9

شماره 1 2015

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023