rib fracture fixation restores inspiratory volume and peak flow in a full thorax human cadaveric breathing model
نویسندگان
چکیده
conclusions negative pressure inspiration is significantly impaired by an unstable chest wall. restoring mechanical stability of the fractured ribs improves respiratory outcomes similar to baseline values. results a wide variation in the mean inspiratory volumes and peak flows were measured between specimens; however, the effect of a flail chest wall and the subsequent internal fixation of the unstable rib fractures was consistent across all samples. compared to the intact chest wall, the inspiratory volume decreased by 40 ± 19% in the flail chest model (p = 0.04). open reduction and internal fixation of the flail chest returned the inspiratory volume to 130 ± 71% of the intact chest volumes (p = 0.68). a similar 35 ± 19% decrease in peak flows was seen in the flail chest (p = 0.007) and this returned to 125 ± 71% of the intact chest following orif (p = 0.62). objectives using a novel full thorax human cadaveric breathing model, we sought to explore the effect of flail chest injury and subsequent rib fracture fixation on respiratory outcomes. patients and methods we used five fresh human cadavers to generate negative breathing models in the left thorax to mimic physiologic respiration. inspiratory volumes and peak flows were measured using a flow meter for all three chest wall states: intact chest, left-sided flail chest (segmental fractures of ribs 3 - 7), and post-fracture open reduction and internal fixation (orif) of the chest wall with a pre-contoured rib specific plate fixation system. background multiple rib fractures cause significant pain and potential for chest wall instability. despite an emerging trend of surgical management of flail chest injuries, there are no studies examining the effect of rib fracture fixation on respiratory function.
منابع مشابه
Rib Fracture Fixation Restores Inspiratory Volume and Peak Flow in a Full Thorax Human Cadaveric Breathing Model
BACKGROUND Multiple rib fractures cause significant pain and potential for chest wall instability. Despite an emerging trend of surgical management of flail chest injuries, there are no studies examining the effect of rib fracture fixation on respiratory function. OBJECTIVES Using a novel full thorax human cadaveric breathing model, we sought to explore the effect of flail chest injury and su...
متن کاملSurgical approaches for rib fracture fixation.
Operative management of thoracic injuries is an increasingly accepted technique, with multiple reports of improved patient outcomes as compared with nonoperative treatment. Despite the evolving support of rib fracture fixation, descriptions of surgical approaches and tactics remain limited. We present this information to allow surgeons to begin or improve treatment of these injuries. In additio...
متن کاملNasal peak inspiratory flow at altitudeFor
Nasal peak inspiratory flow at altitude. P.W. Barry, N.P. Mason, J-P. Richalet. #ERS Journals Ltd 2002. ABSTRACT: The present study investigated whether there are changes in nasal peak inspiratory flow (NPIF) during hypobaric hypoxia under controlled environmental conditions. During operation Everest III (COMEX 997), eight subjects ascended to a simulated altitude of 8,848 m in a hypobaric cham...
متن کاملThe clinical value of peak nasal inspiratory flow, peak oral inspiratory flow, and the nasal patency index.
OBJECTIVES/HYPOTHESIS The aim of this study was to ascertain the most reliable objective measurement for the assessment of nasal patency by investigating the relationship between peak nasal inspiratory flow, peak oral inspiratory flow, and the nasal patency index in relation to the patient's subjective perception regarding nasal obstruction. STUDY DESIGN Prospective cohort study. METHODS Th...
متن کاملPeak inspiratory flow through Turbuhaler in acute asthma.
Efficient use of dry powder inhalers, such as Turbuhaler, is dependent on the generation of adequate inspiratory flow. It is not clear whether patients with acute asthma are able to generate adequate flow. Peak inspiratory flow (PIF) was measured through an empty Turbuhaler, and without this device, in 99 adults presenting to hospital with acute exacerbations of asthma. Where possible, patients...