effect of 0.2% chlorhexidine on microbial and fungal contamination of dental unit waterlines
نویسندگان
چکیده
background: it is known that dental unit waterline can be a source of infection. the aim of this study was to evaluate the effi cacy of a mouthwash, chlorhexidine, in controlling microbial and fungal contamination of dental unit waterlines. materials and methods: in the present experimental study, the water in high-speed handpieces and air/water syringes of 35 dental units in a dental school was investigated microbiologically. five of the units and one tap water served as controls; 100-200-ml water samples were collected aseptically in sterile containers in the morning after a 2-min purge. water reservoir bottles were emptied and 50 ml of 0.2% chlorhexidine mouthwash was introduced into the tank. then the water syringe was used to fl ush the waterline until the pink-colored chlorhexidine was observed to fl ow from the water syringe. before the next day’s session and before the students used the unit, two water samples from the water syringe and water turbine was collected. the samples were transferred to the laboratory. after 48 h at 37°c, the microbial colonies were counted. the number of these colonies was evaluated using colony forming unit cfu. data were analyzed with mann — whitney u test and spss 13.5 statistical program. the statistical signifi cance was defi ned at p ≤ 0.05. results: all 35 units were contaminated before chlorhexidine use; no contamination was detected after adding chlorhexidine to the waterlines of the units. after week 1, 28 of the 30 treated dental unit waterlines (duwls) had values of cfu/ml less than 200. conclusion: the present study showed that the use of chlorhexidine could reduce microbial counts in dental unit waterlines. key words: antibacterial, antifungal, chlorhexidine, infection control, dental
منابع مشابه
Effect of 0.2% chlorhexidine on microbial and fungal contamination of dental unit waterlines
BACKGROUND It is known that dental unit waterline can be a source of infection. The aim of this study was to evaluate the efficacy of a mouthwash, chlorhexidine, in controlling microbial and fungal contamination of dental unit waterlines. MATERIALS AND METHODS In the present experimental study, the water in high-speed handpieces and air/water syringes of 35 dental units in a dental school was...
متن کاملMicrobial contamination of dental unit waterlines.
The specific structure of dental units favours the presence of biofilm and microbial contamination of the dental unit waterlines (DUWL) water. The ability of bacteria to colonize surfaces and to form biofilm in water supply tubes, including DUWL, is a common phenomenon, which has been well documented, just as with difficulties in biofilm removal and prevention of its regrowth. Microorganisms fr...
متن کاملMicrobial contamination in dental unit waterlines.
The quality of water in a dental unit is of considerable importance because patients and dental staff are regularly exposed to water and aerosol generated from the dental unit. The aim of this study was to evaluate the occurrence of microbial contamination in dental unit waterlines. Water samples were collected aseptically from the waterlines (reservoir, triple-syringe, high-speed) of 15 dental...
متن کاملMicrobial contamination of dental unit waterlines: the scientific argument.
The quality of dental unit water is of considerable importance since patients and dental staff are regularly exposed to water and aerosols generated from the dental unit. The unique feature of dental chair water lines is the capacity for rapid development of a biofilm on the dental water supply lines combined with the generation of potentially contaminated aerosols. The biofilm, which is derive...
متن کاملBacterial contamination of dental unit waterlines
Safety of patients and dental personnel requires the appropriate microbiological water quality in dental units. During treatment, patients and dental workers are exposed both to direct contact with bacteria-contaminated water in the form of splatter and with contaminated water aerosol emitted during work by unit handpieces, including rotating and ultrasonic instruments. The aim of the study was...
متن کاملEffect of Different Disinfection Protocols on Microbial and Biofilm Contamination of Dental Unit Waterlines in Community Dental Practices
Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfectio...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
dental research journalجلد ۱۱، شماره ۳، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023