near visual performance results of the accommodating intraocular lens (tetraflex)® in comparison to monofocal foldable intraocular lens

نویسندگان

فیروزه رحیمی

firoozeh rahimi الهام قهاری

elham ghahari محمدناصر هاشمیان

mohammad naser hashemian محمدرضا فلاح

mohammad reza fallah حیدر سیاتیری

چکیده

purpose : to evaluate the near visual performance of an accommodative intraocular lens (iol) tetraflex, in comparison to a standard monofocal foldable iol in cataract surgery. setting: eye research center , farabi eye hospital , department of ophthalmology, tehran university of medical sciences, iran . methods : forty six eyes of 23 patients with cataract underwent phacoemulsification and accommodative iol (tetraflex) implantation bilaterally (case group). the same number of age-matched control group were implanted a foldable monofocal iol bilaterally (control group). outcome measures were uncorrected distance visual acuity (ucdva), uncorrected near visual acuity (ucnva), manifest refraction, best corrected distance visual acuity (bcdva), distance corrected near visual acuity (dcnva), and the amplitude of accommodation up to 6 months after surgery. results : the final bcdva was better than 20/25 in all eyes. mean±standard deviation (sd) dcnva in the accommodative iol group (0.69±0.25) was significantly higher than monofocal foldable iol (0.18±0.09) six months following surgery (p<0.001). eighty nine percent (41 eyes of 46) of the accommodative iol group achieved dcnva of 20/40 or better 6 months after surgery. at 1 month after surgery, mean±sd accommodation in the case group was 3.86±1.11 d compared to 0.27±0.18 d in the control group (p<0.001). six months after operation, 95.7% of the patients in the case group had 2.5 d or more accommodation compared to a mean of 0.48 d in the control group. conclusion : the accommodative iol provides both enhanced near vision and good distance vision 6 month after surgery. it seems that patient&apos;s dependence to near add will be decreased and they can have a good range of clear vision.  iranian journal of ophthalmology 200921(3):5-10 © 2009 by the iranian society of ophthalmology

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Near Visual Performance Results of the Accommodating Intraocular Lens (Tetraflex)® in Comparison to Monofocal Foldable Intraocular Lens

Purpose: To evaluate the near visual performance of an accommodative intraocular lens (IOL); Tetraflex, in comparison to a standard monofocal foldable IOL in cataract surgery. Setting: Eye Research Center, Farabi Eye Hospital, Department of Ophthalmology, Tehran University of Medical Sciences, Iran. Methods: Forty six eyes of 23 patients with cataract underwent phacoemulsification and accommoda...

متن کامل

SCIENTIFIC REPORT A dual optic accommodating foldable intraocular lens

Aim: To design an accommodating intraocular lens with extended accommodative range that can be adapted to current standard phacoemulsification and endocapsular implantation technique. Method: Ray tracing analysis and lens design; cadaver eye implantation. Results: Ray tracing analysis indicated that axial movement of an exaggerated converging anterior optic linked by spring loaded haptics to a ...

متن کامل

Visual Simulation: application to monofocal intraocular lens analysis

It is necessary to introduce some optical concepts before discuss about the different applications of adaptive optics (AO) in human vision. Wave aberration1 is defined as the difference between the perfect (spherical) and the actual wavefront (WF) for each point over the pupil. Figure 1 shows this concept schematically. AO may be defined as an optical system which adapts to compensate aberratio...

متن کامل

Mechanism of action of the tetraflex accommodative intraocular lens.

PURPOSE To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, a...

متن کامل

Visual performance of Acrysof ReSTOR compared with a monofocal intraocular lens following implantation in cataract surgery

The aim of this study was to compare the visual performance of Acrysof ReSTOR and Acrysof Natural intraocular lenses (IOLs) following cataract surgery. A randomized prospective study was performed in which 64 eyes (51 patients) were divided randomly into two groups. Monofocal IOLs (Acrysof Natural) were implanted into 34 eyes (27 patients) and multifocal IOLs (Acrysof ReSTOR) were implanted int...

متن کامل

Clinical outcomes and functional visual performance: comparison of the ReSTOR apodised diffractive intraocular lens to a monofocal control.

AIMS To compare clinical outcomes of patients bilaterally implanted with SN60D3 intraocular lenses (IOLs) with outcomes of bilateral monofocal controls, and to determine the validity of implanting an apodised diffractive lens in a healthy patient population. METHODS Six unmasked US investigators prospectively enrolled 72 patients aged </=70 years with bilateral cataracts in otherwise healthy ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of current ophthalmology

جلد ۲۱، شماره ۳، صفحات ۵-۱۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023