purpose: to evaluate residual refractive errors after cataract surgery and its determinant factors at farabi eye hospital, tehran. methods: simple random sampling was done among cataract surgery scheduled patients over a 4 year period (2003-2006). exclusion criteria were uveitis, previous intraocular surgery and ocular trauma. after applying the exclusion criteria, 423 patients were studied. lens calculation was performed using the srk-ii formula. unexpected refractive errors were defined as the difference between postoperative refractive errors with target refraction. mean and percentage of this variable were reported based on 0.5, 1 and 2 d of ametropia. results: of 558 studied patients, 78.1% had biometric data before and refractive data after surgery. mean absolute unpredictable refractive error was 0.84±0.89 d. eyes with normal axial length (al) had the least (0.76±0.84) and those with long al had the most unpredictable refractive errors (p<0.001). 45.9%, 73.9%, and 91.7% of the study cases had refractive errors within 0.5, 1 and 2 d of emmetropia, respectively. eyes with short al had positive refraction and those with long al had negative refraction after surgery. the majority of keratometric astigmatism followed extra-capsular surgery while the least measures were associated with phacoemulsification (p<0.001). conclusion: axial length was one of the important factors influencing residual refractive errors after cataract surgery. unpredictable refractive errors were more common in eyes with long and short al than those with normal al.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Managing residual refractive error after cataract surgery.

We present a review of keratorefractive and intraocular approaches to managing residual astigmatic and spherical refractive error after cataract surgery, including laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), arcuate keratotomy, intraocular lens (IOL) exchange, piggyback IOLs, and light-adjustable IOLs. Currently available literature suggests that laser vision correc...

متن کامل

Investigation of visual acuity and residual refractive error after cataract surgery in patients with senile cataract by phacoemulsification

Background and Aim: Vision improvement and reduction of refractive errors are considered as important goals of cataract surgery. The purpose of this study was to evaluate residual refractive errors after cataract surgery in the patients with senile cataract in Shahid Rahimi Hospital in Khorramabad City between 2017 and 2018. Material and Methods: This cross-sectional study included 178 patients...

متن کامل

Clinical Outcomes of an Optimized Prolate Ablation Procedure for Correcting Residual Refractive Errors Following Laser Surgery

PURPOSE The purpose of this study was to investigate the clinical efficacy of an optimized prolate ablation procedure for correcting residual refractive errors following laser surgery. METHODS We analyzed 24 eyes of 15 patients who underwent an optimized prolate ablation procedure for the correction of residual refractive errors following laser in situ keratomileusis, laser-assisted subepithe...

متن کامل

Surgical options for correction of refractive error following cataract surgery

Refractive errors are frequently found following cataract surgery and refractive lens exchange. Accurate biometric analysis, selection and calculation of the adequate intraocular lens (IOL) and modern techniques for cataract surgery all contribute to achieving the goal of cataract surgery as a refractive procedure with no refractive error. However, in spite of all these advances, residual refra...

متن کامل

posterior capsule opacification after cataract surgery and its determinants

purpose : a review of posterior capsule opacification (pco) after cataract surgery and some affecting factors methods : a cross-sectional study was designed to study cataract patients who underwent cataract surgery between 2003 and 2006 in farabi eye hospital, tehran, iran. random sampling was done. those with a history of uveitis, intraocular surgery, and eye trauma were excluded from the stud...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
بینا

جلد ۱۵، شماره ۴، صفحات ۲۶۳-۲۷۴

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023