keratic precipitate morphology in various uveitic entities: a confocal scan study
نویسندگان
چکیده
purpose: to characterize keratic precipitate (kp) morphology in different forms of uveitis. methods: one hundred and twenty nine eyes of 93 patients with different forms of uveitis underwent confocal scan and the morphology of kps were determined. differences in kp morphologies among different uveitic groups were evaluated. results: age ranged from 14 to 67 years (mean: 32.5±11.2) and 58 cases (62.36%) were female, 38.7% had bilateral uveitis. almost all types of uveitis disclosed predominantly stippled and globular kps. dendritiform kps were more common in infectious uveitis (p=0.053) and smooth-rounded kps were significantly more common in non-infectious uveitis (p<0.001). dendritiform kps were observed more commonly in nongranulomatous uveitis than granulomatous ones (p=0.005). smooth-rounded kps were more common in chronic uveitis than acute forms (p<0.001). the predominant morphology of kps in fuchs heterochromic iridocyclitis (fhic) were dendritiform (80.0%) and infiltrating (78.0%). the most commonly observed morphology of kps in intermediate uveitis were dendritiform (56.3%) and smooth-rounded (56.3%). cruciform kps were more frequently seen in cases with fhic (60.0%). morphologic features in bilateral cases were similar. conclusion: kp morphologies are diverse in different forms of uveitis. some forms of kps are less specific such as globular and stippled which exist in almost all types of uveitis. confocal scan can play a potential role in differentiating infectious from noninfectious uveitis and granulomatous from nongranulomatous uveitis.
منابع مشابه
Confocal Scan Features of Keratic Precipitates in Granulomatous versus Nongranulomatous Uveitis
PURPOSE To compare the morphologic features of keratic precipitates (KPs) by confocal microscopy in granulomatous versus nongranulomatous noninfectious uveitis. METHODS KP morphology was determined by confocal scan in patients with noninfectious granulomatous and noninfectious nongranulomatous uveitic cases. RESULTS One hundred and twenty-seven eyes of 90 subjects with noninfectious uveitis...
متن کاملthe confocal scan features of keratic precipitates in fuchs’ heterochromic iridocyclitis
purpose: to report confocal scan features of keratic precipitates (kps) in fuchs’ heterochromic iridocyclitis (fhic). methods: in this descriptive study, corneal confocal scan was performed to characterize kps in patients with fhic referred to labbafinejad medical center from november 2005 to march 2007. polymerase chain reaction (pcr) for herpes simplex virus, herpes zoster virus, toxoplasma g...
متن کاملkeratocyte density in keratoconus and post-lasik corneas with and without keratectasia; a confocal scan study
purpose: to compare keratocyte density in stromal layers of the cornea in keratoconus, post-lasik keratectasia, lasik without keratectasia, and normal corneas by confocal scan. methods: thirty-one unscarred corneas from 22 patients with keratoconus, 24 clear corneas from 17 cases with post-lasik keratectasia, 12 corneas from 7 lasik cases without keratectasia, and 26 corneas from 13 normal subj...
متن کاملa study of baudrillards ideas in brian moores fiction
پیدایش مرحله ی جدیدی از نظام سرمایه داری بعد از جنگ جهانی دوم همزمان است با ظهور عصر اطلاعات و رسانه جمعی. در چنین جامعه ای سیر آزادانه ی نشانه ها در فضای بی اساس مجازی بر سرعت فرسایش واقعیت می افزاید. به اعتقاد بودریار، فقدان واقعیت به واسطه ی شبیه سازی آن و تولید حاد واقعیت (hyperreality) پنهان خواهد ماند. این پژوهش بر آن است که جامعه فرانوین توصیف شده در سه رمان بریان مور را با توجه به نظر...
15 صفحه اولnon-linear study of various slit shear walls in steel structures
seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...
15 صفحه اولDesign and Performance of a Multi-Point Scan Confocal Microendoscope.
Confocal fluorescence microendoscopy provides high-resolution cellular-level imaging via a minimally invasive procedure, but requires fast scanning to achieve real-time imaging in vivo. Ideal confocal imaging performance is obtained with a point scanning system, but the scan rates required for in vivo biomedical imaging can be difficult to achieve. By scanning a line of illumination in one dire...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
بیناجلد ۱۶، شماره ۳، صفحات ۲۰۲-۲۰۹
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023