comparison of gradient ac/a ratio with different deviation measurement techniques
نویسندگان
چکیده
purpose: to compare the effect of different deviation measurement techniques and different lens powers on gradient accommodative convergence to accommodation (ac/a) ratio. methods: we randomly selected 78 eligible students of different majors from zahedan university of medical sciences. following retinoscopy for refractive errors, alternate prism cover test, von graefe and maddox rod without additional lenses and with ±1, ±2 and ±3 d lenses were performed for measurement of deviation at near and determination of gradient ac/a ratio. data were analyzed using within subject factorial repeated measurement anova and correlation tests. results: mean ac/a ratio was 3.6, 3.7 and 4 prism diopter to diopter using alternate cover test, maddox rod and von graefe methods, respectively (p=0.2). the highest and lowest ac/a ratios were related to von graefe method with +3d and cover test with -1d lens power, respectively. only differences between ac/a ratios with -1 and +2 lenses as well as with -1 and +3d were significant (p<0.05). for all different deviation measurement methods, ac/a ratios with plus lenses were higher than minus lenses. conclusions: the type of deviation measurement method had no effect on ac/a ratio but selected lens power affected the results. we recommend using 2 or 3 diopter instead of 1 diopter lenses to avoid possible effects of depth of focus.
منابع مشابه
Comparison of different types of rotor for density-gradient techniques.
Centrifugal separations can be classified into three categories, namely differential pelleting, rate-zonal centrifugation and isopycnic centrifugation. Although differential pelleting is the most widely used technique, it has only a limited potential for providing the investigator with purified material. Thus only the last two techniques, both of which involve separations on density gradients, ...
متن کاملcomparison of the amount of debris extruded apically in two rotary techniques: flexmaster and m2
چکیده ندارد.
15 صفحه اولComparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement
Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...
متن کاملComparison of different TBI techniques in terms of dose homogeneity
Introduction: Total body irradiation (TBI) is a form of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression. Since the target in TBI is the whole body so a uniform dose distribution throughout the entire body during TBI is necessary. As recommended by AAPM dose variation must be within ±10% of prescription dose. A revi...
متن کاملa comparison of teachers and supervisors, with respect to teacher efficacy and reflection
supervisors play an undeniable role in training teachers, before starting their professional experience by preparing them, at the initial years of their teaching by checking their work within the proper framework, and later on during their teaching by assessing their progress. but surprisingly, exploring their attributes, professional demands, and qualifications has remained a neglected theme i...
15 صفحه اولInterpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions
Introduction: The head scatter factor (Sc) is one of the important parameters for monitor unit (MU) calculation. There are multiple factors that impact the Sc values, such as, head structures, back scattering in to dose monitoring chambers, wedges and so on. This study aimed to investigate the variations of SC with different build-up cap materials, wall thickness, Source to ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
بیناجلد ۱۶، شماره ۴، صفحات ۳۳۰-۳۳۷
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023