sensitivity and specificity of galilei and orbscan in the diagnosis of subclinical keratoconus
نویسندگان
چکیده
purpose: to determine the sensitivity and specificity of posterior corneal elevation in discriminating keratoconus and subclinical keratoconus from normal corneas by galilei and orbscan ii diagnosed on the basis of topography. methods: three groups (keratoconus, subclinical keratoconus and normal) were evaluated with galilei and orbscan ii and results were compared to those obtained by gold standard placido disc-based topography. in one eye of each patient, posterior corneal elevation was measured in the central 3 mm zones using the galilei rotating double scheimpflug camera. posterior corneal elevation in keratoconus and subclinical keratoconus was compared to that in normal corneas. receiver operating characteristic (roc) curves were used to determine the test’s overall predictive accuracy (area under the curve) and to identify optimal posterior corneal elevation cut off points to maximize sensitivity and specificity in discriminating keratoconus and subclinical keratoconus from normal corneas. similar analysis was done using orbscan ii, in the central 5mm zone. results: in galilei mean posterior corneal elevation in the 3 mm zone was statistically higher in keratoconus (50.6 ± 34.5 microns), and subclinical keratoconus (12.8 ± 4.3 microns) versus normal corneas (9.9 ± 4.5 microns). roc curve analyses showed high overall predictive accuracy of posterior elevation for both keratoconus and subclinical keratoconus (area under the curve 98% and 71%, respectively). optimal cutoff points were 18.5 microns for keratoconus and 11.5 microns for subclinical keratoconus. these values were associated with sensitivity and specificity of 92% and 95% respectively for keratoconus, and 64.3% and 75.7% for subclinical keratoconus. in orbscan ii mean posterior corneal elevation in the 5 mm zone was 106.8 ± 43.7 microns in keratoconus, 36.6 ±22.8 microns in subclinical keratoconus and 25 ± 9.2 microns in normal corneas. optimal cutoff points were 50 microns for keratoconus and 33.5 microns for subclinical keratoconus. these values were associated with sensitivity and specificity of 89.1% and 98.6% respectively for keratoconus, and 50% and 85% for subclinical keratoconus. conclusion: posterior corneal elevation very effectively discriminates keratoconus from normal corneas. its accuracy is lower in subclinical keratoconus and thus data concerning posterior elevation should not be used alone to stratify patients with this condition.
منابع مشابه
Sensitivity and Specificity of Posterior and Anterior Corneal Elevation Measured by Orbscan in Diagnosis of Clinical and Subclinical Keratoconus
PURPOSE To determine the sensitivity and specificity of anterior and posterior corneal elevation parameters as determined by Orbscan II (Bausch and Lomb, Rochester, NY, USA) in discriminating between (sub) clinical keratoconus (KCN) and normal corneas. METHODS This prospective case-control study included 28 eyes with subclinical KCN, 65 with clinical KCN and 141 normal corneas. Anterior and p...
متن کاملthe analysis of the role of the speech acts theory in translating and dubbing hollywood films
از محوری ترین اثراتی که یک فیلم سینمایی ایجاد می کند دیالوگ هایی است که هنرپیش گان فیلم میگویند. به زعم یک فیلم ساز, یک شیوه متأثر نمودن مخاطب از اثر منظوره نیروی گفتارهای گوینده, مثل نیروی عاطفی, ترس آور, غم انگیز, هیجان انگیز و غیره, است. این مطالعه به بررسی این مسأله مبادرت کرده است که آیا نیروی فراگفتاری هنرپیش گان به مثابه ی اعمال گفتاری در پنج فیلم هالیوودی در نسخه های دوبله شده باز تولید...
15 صفحه اولthe survey of the virtual higher education in iran and the ways of its development and improvement
این پژوهش با هدف "بررسی وضعیت موجود آموزش عالی مجازی در ایران و راههای توسعه و ارتقای آن " و با روش توصیفی-تحلیلی و پیمایشی صورت پذیرفته است. بررسی اسنادو مدارک موجود در زمینه آموزش مجازی نشان داد تعداد دانشجویان و مقاطع تحصیلی و رشته محل های دوره های الکترونیکی چندان مطلوب نبوده و از نظر کیفی نیز وضعیت شاخص خدمات آموزشی اساتید و وضعیت شبکه اینترنت در محیط آموزش مجازی نامطلوب است.
the crisis of identity in jhumpa lahiris fiction: interpreter of maladies and the namesake
شکل گیری هویت(identity) مقوله مهمی در ادبیات پراکنده مردم(diasporan literature) می باشد. آثار جومپا لاهیری(jhumpa lahiri) ، نویسنده هندی آمریکایی، در سالهای اخیر تحسین منتقدین را به خود معطوف کرده است. وی در این آثار زندگی مهاجران و تلاش آنان برای پیدا کردن جایگاهشان در یک فرهنگ بیگانه را به تصویر کشیده است. این تجربه همواره با احساساتی نظیر دلتنگی برای گذشته، بیگانگی و دوری همراه است. با این ح...
15 صفحه اولideological and cultural orientations in translation of narrative text: the case of hajji baba of isfahan
در میان عواملی که ممکن است ذهن مترجم را هنگام ترجمه تحت تأثیر قرار دهند، می توان به مقوله انتقال ایدئولوژی از طریق متن یا گفتمان اشاره کرد. هدف از این تحقیق تجزیه و تحلیل جنبه های ایدئولوژیکی و فرهنگی متن مبدأ انگلیسی نوشته جیمز موریه تحت عنوان سرگذشت حاجی بابای اصفهانی ( 1823) و ترجمه فارسی میرزا حبیب اصفهانی(1880) بوده است.
منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
بیناجلد ۱۸، شماره ۱، صفحات ۳۹-۴۷
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023