comparison of low dose and standard dose abdominal ct scan in body stuffers
نویسندگان
چکیده
results the study consisted of 40 patients (all men, with mean age of 33.38 ± 7.4 years). ct evaluation with standard dose were positive in 22 patients (55%). only 1 (2.5%) ct scan assigned as unacceptable by each radiologist in low-dose group. noise average of low-dose protocol, was approximately 7 times greater than standard dose group, while dlp and ed are 9.7 times smaller. in comparison with standard dose ct scan, low-dose group had a sensitivity of 86.46%, specificity of 100%, ppv and npv of 100% and 85.71%. background body stuffer determination is an important concern in emergency departments for referred patients with suspicion of swallowing drug packets. because of small packet size, plain radiography is of little value in most patients. on the other hand, abdominal and pelvic ct scan is burdened by high cost and radiation dose. this study was performed to evaluate the sensitivity of low-dose ct scan in comparison with conventional one. so, the former can be used as an alternative screening and follow up tool for suspected body stuffers methods in this prospective study, suspected body stuffers who were referred to radiology department, underwent two different protocols of abdominal and pelvic non-contrast ct scan: low-dose (equivalent dose of conventional abdominal x-ray) and standard dose. standard dose ct scan was considered as the gold standard and low-dose protocol was compared with that for image quality and packet detection rate. discussion accuracy of low-dose ct scan for detection of baggies larger than 1 cm, approaches 100%. therefore, it looks an appropriate screening method for body stuffers, especially when the packages are larger.
منابع مشابه
Standard dose versus low-dose abdominal and pelvic CT: comparison between filtered back projection versus adaptive iterative dose reduction 3D.
PURPOSE To compare the dose and image quality of a standard dose abdominal and pelvic CT with Filtered Back Projection (FBP) to low-dose CT with Adaptive Iterative Dose Reduction 3D (AIDR 3D). MATERIALS AND METHODS We retrospectively examined the images of 21 patients in the portal phase of an abdominal and pelvic CT scan before and after implementation of AIDR 3D iterative reconstruction. Th...
متن کاملLow-dose CT scan screening for lung cancer: comparison of images and radiation doses between low-dose CT and follow-up standard diagnostic CT
OBJECTIVES This study aim to compare image quality and radiation doses between low-dose CT and follow-up standard diagnostic CT for lung cancer screening. METHODS In a single medical institution, 19 subjects who had been screened for lung cancer by low-dose CT before going through follow-up standard diagnostic CT were randomly selected. Both CT image sets for all subjects were independently e...
متن کاملClinical Value of Low Dose CT- Scan in Pediatric Chest Diseases: Adequacy Assessment
Background Radiation dose about 400 times that of standard thoracic computed tomography (CT) in comparison with chest X- ray resulting in different approaches to decrease radiation dose have been established in the last few years to prevent possible side effects especially in children, such as low dose protocols. The aim of this study was assessment of clinical v...
متن کاملThyroid dose and dose reduction method from CT scan of head and neck
Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...
متن کاملComparison of low-dose with standard-dose multidetector CT in cervical spine trauma.
BACKGROUND AND PURPOSE The purpose of this work was to evaluate the possible use of low-dose multidetector CT (MDCT) in cervical clearance of patients with blunt trauma. MATERIALS AND METHODS A total of 191 patients underwent cervical spine MDCT with 6- and 16-MDCT: standard-dose (n = 51) and low-dose MDCT with tube current modulation at high (n = 70) and low (n = 70) tube voltage (kilovolts)...
متن کاملAccuracy of low dose CT in the diagnosis of appendicitis in childhood and comparison with USG and standard dose CT.
OBJECTIVES Computed tomography should be performed after careful consideration due to radiation hazard, which is why interest in low dose CT has increased recently in acute appendicitis. Previous studies have been performed in adult and adolescents populations, but no studies have reported on the efficacy of using low-dose CT in children younger than 10 years. METHODS Patients (n=475) younger...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiologyجلد ۲۰۱۷، شماره ۵، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023