transcatheter closure of patent ductus arteriosus: initial study on echocardiographic estimation of device size
نویسندگان
چکیده
background: transcatheter occlusion of the patent ductus arteriosus (pda) is a minimally invasive treatment. the appropriate device size is chosen based on the angiographic measurement of the pda . the current study aimed to assess the relationship between the transthoracic echocardiographic (tte) measurements of the pda prior to the occlusion procedure and the actual size of the deployed device. methods: we reviewed the available records of 7 patients (2 male) who underwent the procedure at our institution (mean age: 21 ± 12.7 years, range: 7 to 46 years). pda closure was performed successfully using the amplatzer duct occluder (n = 5) and its chinese copycat, cardi-o-fix occluder (n = 2). results: the tte measurement of the aortic end diameter of the pda showed a good linear regression correlation with the size of the implanted duct occluder [duct occluder size = 0.543 + (0.941× tte measured diameter), r = 0.907; p value ≤ 0.01]. conclusion: tte can provide a good estimation of the size of the amplatzer duct occluder.
منابع مشابه
Transcatheter Closure of Patent Ductus Arteriosus: Initial Study on Echocardiographic Estimation of Device Size
BACKGROUND Transcatheter occlusion of the patent ductus arteriosus (PDA) is a minimally invasive treatment. The appropriate device size is chosen based on the angiographic measurement of the PDA. The current study aimed to assess the relationship between the transthoracic echocardiographic (TTE) measurements of the PDA prior to the occlusion procedure and the actual size of the deployed device....
متن کاملTranscatheter device closure of patent ductus arteriosus.
OBJECTIVE To determine the efficacy, safety and immediate complications encountered during percutaneous device closure of patent ductus arteriosus (PDA). STUDY DESIGN Case series. PLACE AND DURATION OF STUDY Department of Paediatric Cardiology, AFIC/NIHD, Rawalpindi, from January 2005 to December 2010. METHODOLOGY Consecutive 500 patients who underwent attempted transcatheter PDA device c...
متن کاملTranscatheter Closure of Patent Ductus Arteriosus
Background The USCI PDA Umbrella is a device to close patent ductus arteriosus (PDA) by a transcatheter technique. Human clinical trials have shown excellent efficacy in reducing or eliminating the PDA shunt, but concerns remain about the risk of infection with this device. The purpose of this study was to evaluate the risk of infection using an animal model. Methods and Results Susceptibility ...
متن کاملTranscatheter Closure of Patent Ductus Arteriosus
Patent ductus arteriosus (PDA) constitutes 6 to 11% of all congenital heart defects. While surgical ligation and video-assisted, thoracoscopic interruption of PDA are still available, transcatheter occlusion of PDAs has recently assumed a major role in closure of PDA. A large number of devices have been designed and tested both in animal models and human subjects, but only few devices (free and...
متن کاملTranscatheter closure of patent ductus arteriosus.
More than three decades have passed since the introduction of transcatheter devices for closure of patent ductus arteriosus, and many occluders have been made available since then. The ideal requirements of any procedure are a user-friendly technique, optimum success rate, no residual anomaly, minimal morbidity/mortality, and comparability or superiority to the existing conventional modality of...
متن کاملTranscatheter closure of the patent ductus arteriosus.
Patent ductus arteriosus (PDA) is one of the most common congenital heart defects. Although surgery is still required in symptomatic neonates, the majority of older infants and children can undergo safe and effective transcatheter device closure on an out-patient basis. First described in 1967, over the past four decades, numerous devices have been specifically developed for this purpose. This ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
the journal of tehran university heart centerجلد ۵، شماره ۴، صفحات ۱۹۹-۲۰۱
میزبانی شده توسط پلتفرم ابری doprax.com