when can we release the amplatzer ductal occluder (ado) safely?

نویسندگان

mehdi ghaderian emam hosein medical, educational and research center, esfahan university of medical sciences, esfahan, iran and rajaie cardiovascular, medical and research center, iran university of medical sciences, tehran, iran.

mahmood merajie rajaie cardiovascular, medical andresearch center, iran university of medical sciences, tehran, iran.

hodjjat mortezaeian rajaie cardiovascular, medical andresearch center, iran university of medical sciences, tehran, iran.

mohammadyoosef aarabi-moghadam rajaie cardiovascular, medical andresearch center, iran university of medical sciences, tehran, iran.

چکیده

background: the ductus arteriosus connects the main pulmonary trunk to the descending aorta. the incidence of isolated patent ductus arteriosus (pda) in full-term infants is about 1 in 2000. the amplatzer ductal occluder (ado) is recommended for pdas with sizes larger than 2 mm. in this procedure, we must confirm the ado position in pda by aortogram from the arterial line. the purpose of this study was to determine the optimal release time of the ado in the pda closure procedure, especially in the absence of an arterial line for post-pda aortography. methods: this study recruited all patients scheduled to undergo pda transcatheter closure with the ado between september 2009 and september 2012 in our center. age, weight, pda diameter, systolic and diastolic pulmonic pressures, fluoroscopy time, and total angiographic time were studied. major complications such as mortality and vascular complications were considered. results: w e studied 237 patients in our investigation. we had 130 female and 107 male patients at a mean age of 34.3 ± 40.6 months and mean weight of 14.2 ± 7.8 kg. pda sizes ranged from 2.1 to 6.2 mm and its mean was 3.7 ± 1.8 mm. mean of fluoroscopy time was 11.4 ± 9.7 min and mean of total angiographic time was 42.0 ± 12.3 min. there were no significant complications. conclusion: w e herein describe a new sign, which proved extremely helpful during our pda closure procedures with the ado. by considering the angle between the ado and the cable during the procedure, the operator can release the ado safely.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

When Can We Release the Amplatzer Ductal Occluder (ADO) Safely?

BACKGROUND The ductus arteriosus connects the main pulmonary trunk to the descending aorta. The incidence of isolated patent ductus arteriosus (PDA) in full-term infants is about 1 in 2000. The Amplatzer Ductal Occluder (ADO) is recommended for PDAs with sizes larger than 2 mm. In this procedure, we must confirm the ADO position in PDA by aortogram from the arterial line. The purpose of this st...

متن کامل

Transcatheter Closure of Large Patent Ductus Arteriosus Using the Amplatzer Ductal Occluder

Background: Coils are suitable for the closure of a small patent ductus arteriosus (PDA) but are not recommended for a large PDA. We reported our initial experience of transcatheter closure of a large PDA using the Amplatzer ductal occluder (ADO). Methods: From April 2002 to October 2006, all patients with ductal size greater than 3.5 mm undergoing transcatheter closure of PDA using the ADO wer...

متن کامل

Transcatheter Closure of a Muscular Ventricular Septal Defect By Amplatzer Ductal Occluder II

Ventriküler septal defektler transkateter tedavide kapatılması gereken bir defekt olarak görülmektedir. Son yıllarda yeni cihazların bulunması ile birçok merkezde ventriküler septal defektlerin perkütan kapatılması cesaretlendiren sonuçlarla uygulanmaktadır. Amplatzer oklüder sistemlerin son yıllarda kullanılmaya başlaması ile birlikte implantasyon sayılarında artma olmuştur. Bunun yanısıra, mü...

متن کامل

When Can We Lift the Coronavirus Pandemic Restrictions? Not Before Taking These Steps

When Can We Lift the Coronavirus Pandemic Restrictions? Not Before Taking These Steps. The American Enterprise Institute, a public policy think tank, recently released a report co-written by former U.S. Food and Drug Administration commissioner Scott Gottlieb that offers a four-phase “road map to reopening.” The first phase involves slowing the spread of new infections with physical distancing ...

متن کامل

Transcatheter retrieval of embolized AMPLATZER Septal Occluder.

In selected patients, transcatheter closure of atrial septal defects with the AMPLATZER Septal Occluder has yielded excellent results. However, there is a slight risk of device embolization after deployment. We report the case of a 26-year-old woman in whom an embolized AMPLATZER device was retrieved percutaneously from the right pulmonary artery. We also discuss important technical principles ...

متن کامل

Changes in serial laboratory test results in snakebite patients: when can we safely exclude envenoming?

OBJECTIVES To determine which laboratory tests are first associated with severe envenoming after a snakebite, when (ie, how long after the bite) the test results become abnormal, and whether this can determine a safe observation period after suspected snakebite. DESIGN, PATIENTS AND SETTING Prospective cohort study of 478 patients with suspected or confirmed snakebite recruited to the Austral...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
the journal of tehran university heart center

جلد ۸، شماره ۴، صفحات ۱۸۲-۱۸۶

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023