depth dose calculation of holmium-166 for different shape source by varskin3 code

نویسندگان

ali asghar mowlavi

azam afzalifar

naser afzalifar

ehsan kashani

چکیده

introduction: using beta emitter radionuclide is a useful therapeutic modality in the treatment of skin cancers in areas which are difficult to cure by other methods. the aim of this research is to evaluate the tissue response to beta rays of 166ho and determine the feasibility of beta emitting radionuclide for treatment of skin cancers. methods: in this work, we have calculated depth dose distribution of 166ho using varskin3 code. the code has been run for various input parameters to calculate absorbed depth dose for different shape of source. results: absorbed depth dose variation has been calculated for166ho beta emitter, in different shape of sources such as slab, spherical, cylindrical and 2-d disk shapes. comparison of the result for different shape sources has been presented. conclusion: the result shows that 2-d disk source induces damage to skin cells more than other shape of sources. these computational and lee et al. experimental results are shown that 166ho radionuclide treatment is very useful for skin cancer therapy. one of advantages of using 166ho radionuclide is that no adverse effect on underlying bone and soft tissue due to the physical characteristics of beta rays, high linear energy transfer or rapid depth dose fall off is observed.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Depth dose calculation of Holmium-166 for different shape source by VARSKIN3 code

  Introduction: Using beta emitter radionuclide is a useful therapeutic modality in the treatment of skin cancers in areas which are difficult to cure by other methods. The aim of this research is to evaluate the tissue response to beta rays of 166Ho and determine the feasibility of beta emitting radionuclide for treatment of skin cancers. Methods: In this...

متن کامل

New formula for Calculation of Cobalt-60 Percent Depth Dose

Introduction:  On  the  basis  of  percent  depth  dose  (PDD)  calculation,  the  application  of  dosimetry  in  radiotherapy  has  an  important  role  to  play  in  reducing  the  chance  of  tumor  recurrence. The aim of this study is to introduce a new formula for calculating the centeral axis  percent depth doses of Cobalt-60 beam.   Materials and Methods: In the present study, based on ...

متن کامل

Calculation of depth dose profiles with a track structure code

A prerequisite for applying high-LET radiation like protons or carbon ions to patients is the precise knowledge of absorbed dose, specifically the depth dose distribution. The legal restraints imposed by the authorities requires the Bragg peak position to be reproduced within 0.5 mm and the calculated absorbed dose distribution to agree within 5% (on average) with the measurements. These condit...

متن کامل

new formula for calculation of cobalt-60 percent depth dose

introduction:  on  the  basis  of  percent  depth  dose  (pdd)  calculation,  the  application  of  dosimetry  in  radiotherapy  has  an  important  role  to  play  in  reducing  the  chance  of  tumor  recurrence. the aim of this study is to introduce a new formula for calculating the centeral axis  percent depth doses of cobalt-60 beam.   materials and methods: in the present study, based on ...

متن کامل

Production of Holmium-166 DOTMP: A promising agent for bone marrow ablation in hematologic malignancies

  Intoduction: Therapeutic radiopharmaceuticals are radiolabeled molecules to deliver sufficient doses of ionizing radiation to specific disease sites such as bone metastases, brain and liver tumors and bone marrows malignancies including multiple myeloma. Among some therapeutic radiopharmaceuticals, 166Ho-1,4,7,10 -tetraazacyclo dodecane-1,4,7,10 tetraethy...

متن کامل

X-ray spectra calculation for different target-filter of mammograms using MCNP Code

 ABSTRACTBackground: An electron beam generated X-ray spectrum consists of characteristic X-ray and continuous bermsstrahlung. The aim of this research is calculating and comparing X-ray spectra for different target filter of mammograms. Materials and Methods: Monte Carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the X-ray spectra. MC...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of nuclear medicine

ناشر: tehran university of medical sciences

ISSN 1681-2824

دوره 18

شماره 1 2010

کلمات کلیدی
[ ' h o l m i u m ' , 1 6 6 , ' v a r s k i n 3 c o d e ' , ' s k i n c a n c e r ' , ' s o u r c e s h a p e ' ]

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023