implant surface temperature changes during er:yag laser irradiation with different cooling systems.
نویسندگان
چکیده
peri-implantitis is one of the most common reasons for implant failure. decontamination of infected implant surfaces can be achieved effectively by laser irradiation; although the associated thermal rise may cause irreversible bone damage and lead to implant loss. temperature increments of over 10ºc during laser application may suffice for irreversible bone damage.the purpose of this study was to evaluate the temperature increment of implant surface during er:yag laser irradiation with different cooling systems.three implants were placed in a resected block of sheep mandible and irradiated with er:yag laser with 3 different cooling systems namely water and air spray, air spray alone and no water or air spray. temperature changes of the implant surface were monitored during laser irradiation with a k-type thermocouple at the apical area of the fixture.in all 3 groups, the maximum temperature rise was lower than 10°c. temperature changes were significantly different with different cooling systems used (p<0.001).based on the results, no thermal damage was observed during implant surface decontamination by er:yag laser with and without refrigeration. thus, er:yag laser irradiation can be a safe method for treatment of periimplantitis.
منابع مشابه
Implant Surface Temperature Changes during Er:YAG Laser Irradiation with Different Cooling Systems
OBJECTIVE Peri-implantitis is one of the most common reasons for implant failure. Decontamination of infected implant surfaces can be achieved effectively by laser irradiation; although the associated thermal rise may cause irreversible bone damage and lead to implant loss. Temperature increments of over 10ºC during laser application may suffice for irreversible bone damage. PURPOSE OF STUDY ...
متن کاملNumerical Modeling of Tissue Coagulation during Laser Irradiation Controlled by Surface Temperature
The numerical analysis of thermal process proceeding in biological tissue during a laser irradiation controlled by surface temperature of tissue is presented. Heat transfer in the tissue is assumed to be transient and one-dimensional. The internal heat sources resulting from laser irradiation based on the Beer law are taken into account. Perfusion rate and effective scattering coefficient are t...
متن کاملMeasurement of human brain temperature changes during cooling
Introduction Therapeutic brain hypothermia is used with increasing frequency as a tool to mitigate neurologic injury [1]. It has been shown that moderate cooling of the brain after hypoxia-ischemia can reduce damage and improve functional outcome [2, 3]. Recently a new method for selective brain cooling was described and prototype device was tested on the pigs [4, 5]. Brain temperature decreasi...
متن کاملRadiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study
Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...
متن کاملTemperature Changes Produced in Tissue During Ultrasonic Irradiation
This paper is concerned with the technique of temperature measurement in living tissue during irradiation by high intensity ultrasound. The interpretation of data obtained by the use of thermocouples is presented. The specific biological object used in this study is the spinal cord of rat exposed by laminectomy. This particular preparation serves to illustrate the relative importance of the hea...
متن کاملThermal increment due to ErCr:YSGG and CO2 laser irradiation of different implant surfaces. A pilot study.
OBJECTIVE An evaluation and comparison is made of the thermal increment at different implant surfaces during irradiation with CO2 and ErCr:YSGG lasers. STUDY DESIGN Five threaded and impacted implants with four types of surfaces were inserted in an adult pig rib: two implants with a hydroxyapatite surface (HA) (impacted and threaded, respectively), a machined titanium surface implant (TI mach...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of dentistry, tehran university of medical sciencesجلد ۱۱، شماره ۲، صفحات ۲۱۰-۵
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023