diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects
نویسندگان
چکیده
objectives: this study aimed to compare the diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects. materials and methods: a total of 30 osteotomy sites were prepared in three groups of control, study group 1 with 0.425 mm defects and study group 2 with 0.725 mm defects using the sic and astra tech drill systems with 4.25mm and 4.85mm diameters. small and large defects were randomly created in the coronal 8mm of 20 implant sites; implants (3.4mm diameter, 14.5mm length) were then placed. thirty periapical (pa) radiographs were obtained using digora imaging system (soredex corporation, helsinki, finland), size 2 photostimulable storage phosphor (psp) plate sensors (40.0mm×30.0mm) and scanora software. unprocessed images were inverted using scanora software by applying image inversion and a total of 60 images were obtained and randomly evaluated by four oral and maxillofacial radiologists. data were analyzed using the t-test. results: significant differences were observed in absolute and complete sensitivity and specificity of the two imaging modalities for detection of small and large defects (p<0.05). unprocessed digital images had a higher mean in terms of absolute sensitivity for detection of small defects, complete sensitivity for detection of large peri-implant defects and definite rule out of defects compared with inverted images. conclusion: unprocessed digital images have a higher diagnostic value for detection of small and large peri-implant defects and also for definite rule out of defects compared with inverted images.
منابع مشابه
Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects
OBJECTIVES This study aimed to compare the diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects. MATERIALS AND METHODS A total of 30 osteotomy sites were prepared in three groups of control, study group 1 with 0.425 mm defects and study group 2 with 0.725 mm defects using the SIC and Astra Tech drill systems with 4.25mm and 4.8...
متن کاملdiagnostic accuracy of digitized conventional radiographs by camera and scanner in detection of proximal caries
background and aims. digital radiographs have some advantages over conventional ones. application of digital receptors is not routine yet. therefore, there is a need for digitizing conventional radiographs. the aim of the present study was to compare the diagnostic accuracy of digitized conventional radiographs by scanner and camera in detection of proximal caries. material and methods. three h...
متن کاملdiagnostic and developmental potentials of dynamic assessment for writing skill
این پایان نامه بدنبال بررسی کاربرد ارزیابی مستمر در یک محیط یادگیری زبان دوم از طریق طرح چهار سوال تحقیق زیر بود: (1) درک توانایی های فراگیران زمانیکه که از طریق برآورد عملکرد مستقل آنها امکان پذیر نباشد اما در طول جلسات ارزیابی مستمر مشخص شوند; (2) امکان تقویت توانایی های فراگیران از طریق ارزیابی مستمر; (3) سودمندی ارزیابی مستمر در هدایت آموزش فردی به سمتی که به منطقه ی تقریبی رشد افراد حساس ا...
15 صفحه اولDiagnostic Accuracy of Digitized Conventional Radiographs by Camera and Scanner in Detection of Proximal Caries
BACKGROUND AND AIMS Digital radiographs have some advantages over conventional ones. Application of digital recep-tors is not routine yet. Therefore, there is a need for digitizing conventional radiographs. The aim of the present study was to compare the diagnostic accuracy of digitized conventional radiographs by scanner and camera in detection of proximal car-ies. MATERIALS AND METHODS Thre...
متن کاملDiagnostic Accuracy of Digitized Images Using Different Resolution Settings of Digital Camera in Detection of Proximal Caries
Objective: When none of digital systems and scanners is accessible and it is essential to have digitized images of conventional radiographs, digital cameras can be used. The Aim of this study was to investigate whether digital images obtained by different resolutions of a digital camera are matched to the original radiographs in evaluation of caries. Methods: In this diagnostic accuracy in v...
متن کاملthe effects of time planning and task complexity on accuracy of narrative task performance
هدف اصلی این تحقیق بررسی تاثیر برنامه ریزی زمانی، هم چنین افزایش میزان پیچیدگی تکالیف در نظر گرفته شده بصورت همزمان، بر دقت و صحت و پیچیدگی عملکرد نوشتاری زبان آموزان می باشد. بدین منظور، 50 نفر از دانش آموزان دختر در رده ی سنی 16 الی 18 سال به عنوان شرکت کنندگان در این زمینه ی تحقیق در نظر گرفته شدند و به دو گروه آزمایشی و کنترل بصورت اتفاقی تقسیم شدند. اعضای گروه آزمایشی هر دو تکلیف ساده و پی...
منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of dentistry, tehran university of medical sciencesجلد ۱۲، شماره ۸، صفحات ۵۷۱-۵۷۶
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023