effects of different viewing conditions on radiographic interpretation
نویسندگان
چکیده
objectives : optimum viewing conditions facilitate identification of radiographic details and decrease the need for retakes, patients’ costs and radiation dose. this study sought to evaluate the effects of different viewing conditions on radiographic interpretation. materials and methods: this diagnostic study was performed by evaluating radiograph of a 7mm-thick aluminum block, in which 10 holes with 2mm diameters were randomly drilled with depths ranging from 0.05 mm to 0.50mm. the radiograph was viewed by four oral radiologists independently under four viewing conditions, including a white light viewing light box in a lit room, yellow light viewing light box in a lit room, white light viewing light box in a dark room and yellow light viewing light box in a dark room. number of circular shadows observed on the film was recorded. the data were analyzed by two-way anova. results: the mean number of detected circular shadows was 6.75, 7.5, 7.25 and 7.75 in white light viewing light box in a lit room, white light viewing light box in a dark room, yellow light viewing light box in a lit room and yellow light viewing light box in a dark room, respectively. although the surrounding illumination had statistically significant effect on the radiographic details (p≤0.03), the light color of the viewing light box had no significant effect on visibility of the radiographic details. conclusion: white and yellow light of the viewing light box had no significant effect on visibility of the radiographic details but more information was obtained in a dark room.
منابع مشابه
Effects of Different Viewing Conditions on Radiographic Interpretation
OBJECTIVES Optimum viewing conditions facilitate identification of radiographic details and decrease the need for retakes, patients' costs and radiation dose. This study sought to evaluate the effects of different viewing conditions on radiographic interpretation. MATERIALS AND METHODS This diagnostic study was performed by evaluating radiograph of a 7mm-thick aluminum block, in which 10 hole...
متن کاملRadiographic viewing conditions at Johannesburg Hospital
PURPOSE To measure the luminance level of X-ray viewing boxes and ambient lighting levels in reporting rooms as a quality assurance procedure, and to compare the results with those recommended by the Directorate of Radiation Control, South Africa (DRC), European Commission (EC) and Nordic Radiation Protection Co-operation (NORDIC). MATERIALS AND METHODS All the viewing boxes housed at the Div...
متن کاملthe effect of viewing conditions on reader performance in radiographic images
accurate interpretation of radiographic images is dependent on viewing conditions. recently the number of radiology departments has been increased so it needs to use a workstation for reporting. the aim of this study was assess monitor performance and the effect of viewing conditions on object detection. this investigation aimed to quantify the effects of changes in box brightness and ambient l...
متن کاملthe effects of error correction methods on pronunciation accuracy
هدف از انجام این تحقیق مشخص کردن موثرترین متد اصلاح خطا بر روی دقت آهنگ و تاکید تلفظ کلمه در زبان انگلیسی بود. این تحقیق با پیاده کردن چهار متد ارائه اصلاح خطا در چهار گروه، سه گروه آزمایشی و یک گروه تحت کنترل، انجام شد که گروه های فوق الذکر شامل دانشجویان سطح بالای متوسط کتاب اول passages بودند. گروه اول شامل 15، دوم 14، سوم 15 و آخرین 16 دانشجو بودند. دوره مربوطه به مدت 10 هفته ادامه یافت و د...
15 صفحه اولAccuracy and consistency of radiographic interpretation among clinical instructors using two viewing systems.
Accurate and consistent radiographic interpretation among clinical instructors is needed for assessment of teaching, student performance, and patient care. The purpose of this investigation was to determine if the method of radiographic viewing affects accuracy and consistency of instructors' determinations of bone loss. Forty-one clinicians who provide instruction in a dental school clinical t...
متن کاملthe effects of planning on accuracy and complexity of iranian efl students’ written narrative task performance
this study compared the different effects of form-focused guided planning vs. meaning-focused guided planning on iranian pre-intermediate students’ task performance. the study lasted for three weeks and concentrated on eight english structures. forty five pre-intermediate iranian students were randomly assigned to three groups of guided planning focus-on-form group (gpfg), guided planning focus...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of dentistry, tehran university of medical sciencesجلد ۱۲، شماره ۱۱، صفحات ۸۵۳-۸۵۸
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023