assessment of independent risk factors of developing pneumothorax during percutaneous core needle lung biopsy: focus on lesion depth

نویسندگان

ha-yeon lee department of radiology, hallym university college of medicine, gyeonggi-do, republic of korea

in jae lee department of radiology, hallym university college of medicine, gyeonggi-do, republic of korea; department of radiology, hallym university college of medicine, gyeonggi-do, republic of korea. tel: +82-313803917, fax: +82-313803878

چکیده

conclusion lesion depth from the pleural surface and the presence of emphysema were strongly correlated with the increasing incidence of pneumothorax after ct-guided pcnb. our results may be applicable for the risk management of pcnbs to reduce pneumothorax as a complication. background previous studies identifying risk factors for pneumothorax in percutaneous core needle lung biopsies reported inconsistent and contradictory results. objectives we aimed to identify independent risk factors for pneumothorax associated with computed tomography (ct)-guided percutaneous core needle lung biopsy (pcnb). patients and methods we retrospectively reviewed 591 biopsy procedures for focal lung lesions. risk factors for pneumothorax as a complication after lung biopsy were determined by univariate and multivariate analyses of variables including the patient’s age, gender, lesion depth from the pleural surface, lesion size, lesion location, presence or absence of fissure crossing by the needle, emphysema in the same lobe where the biopsy was performed, and the final diagnosis of the biopsy lesion. results pneumothorax occurred in 100 (16.9%) of 591 procedures. based on univariate analyses, significant risk factors affecting the incidence of pneumothorax were patient gender (p = 0.039), lesion depth from the pleural surface (p < 0.001), fissure crossing by the needle (p = 0.002), and the presence of emphysema (p = 0.009). from the multivariate analysis, an increased rate of pneumothorax was strongly correlated with lesion depth from the pleural surface (odds ratio [or], 1.71; 95% confidence interval [ci], 1.50 - 1.96; p < 0.001) and the presence of emphysema (or, 2.95; 95% ci, 1.73 - 5.04; p < 0.001).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Independent Risk Factors of Developing Pneumothorax During Percutaneous Core Needle Lung Biopsy: Focus on Lesion Depth

BACKGROUND Previous studies identifying risk factors for pneumothorax in percutaneous core needle lung biopsies reported inconsistent and contradictory results. OBJECTIVES We aimed to identify independent risk factors for pneumothorax associated with computed tomography (CT)-guided percutaneous core needle lung biopsy (PCNB). PATIENTS AND METHODS We retrospectively reviewed 591 biopsy proce...

متن کامل

Systemic air embolism during percutaneous core needle biopsy of the lung: frequency and risk factors

BACKGROUND Detection of risk factors for an air embolism in the left atrium, left ventricle, or systemic circulation (systemic air embolism, SAE) during a percutaneous core needle biopsy (PCNB) of the thorax. METHODS In a retrospective observational study, all PCNBs of the thorax in 610 patients between 2007 and 2009 were analyzed. The SmartStep™ technique (General Electric) was used for the ...

متن کامل

Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method.

The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pl...

متن کامل

Incidence and risk factors of delayed pneumothorax after transthoracic needle biopsy of the lung.

STUDY OBJECTIVES To evaluate the incidence and clinical significance of delayed pneumothorax, and to analyze the influence of multiple variables on the rate of delayed pneumothorax associated with transthoracic needle biopsy (TTNB) of the lung. STUDY DESIGN Prospective study. SETTING Tertiary care university hospital. STUDY SUBJECTS Adult patients underwent TTNB from June 2001 to June 200...

متن کامل

Percutaneous transthoracic CT guided biopsies of lung lesions; fine needle aspiration biopsy versus core biopsy

BACKGROUND The purpose of this retrospective study was to compare the results and complication rate in CT guided percutaneous trans-thoracic fine needle aspiration biopsies (FNAB) and core biopsies of lung lesions, and to determine the applicability of these needles. PATIENTS AND METHODS In 242 patients (166 males; 76 females) with mean age of 58.9 years (13-84 years) CT guided biopsies of lu...

متن کامل

PERCUTANEOUS TRANSTHORACIC BIOPSY USING TRU-CUT NEEDLE

Biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. A large-bore 14-gauge Tru-cut needle was used in all patients. Adequate specimens for histologic examination were obtained in 98%. The overall accuracy was 91 % with 9% false negative and no false positive diagnoses. Despite the large size of the needle, the total number of complic...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiology

جلد ۱۳، شماره ۴، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023