diagnostic performance on low dose computed tomography for acute appendicitis among attending and resident radiologists
نویسندگان
چکیده
conclusion attending radiologists could diagnose acute appendicitis accurately on ne-ldct. performance of senior residents on ne-ldct is better than junior residents and comparable to attending radiologists. results diagnostic performances for acute appendicitis were not statistically different for attending radiologists at both examinations. better performance was noted on the ce-sdct with a borderline significant difference (p = 0.05) for senior radiology resident. no statistical difference of auc values was observed between attending radiologists and fourth year resident on both examinations. statistically significant differences of auc values were observed between attending radiologists and first year residents (p = 0.001 ~ 0.018) on ne-ldct. diagnostic accuracies of acute appendicitis on ne-ldct for each reader were not significantly related to bmi or noise. objectives to compare inter-observer and intra-observer differences of diagnostic performance on non-enhanced ldct (ne-ldct) and contrast-enhanced standard dose ct (ce-sdct) for acute appendicitis among attending and resident radiologists. patients and methods this retrospective study included 101 patients with suspected acute appendicitis who underwent ne-ldct and ce-sdct. the ct examinations were interpreted and recorded on a five-point scale independently by three attending radiologists and three residents with 4, 1 and 1 years of training. diagnostic performance for acute appendicitis of all readers on both examinations was represented by area under receiver operating characteristic (roc) curves. inter-observer and intra-observer auc values were compared using jackknife froc software on both modalities. the diagnostic accuracy of each reader on ne-ldct was compared with body mass index (bmi) subgroups and noise using independent t test. background low-dose computed tomography (ldct) techniques can reduce exposure to radiation. several previous studies have shown that radiation dose reduction in ldct does not decrease the diagnostic performance for appendicitis among attending radiologists. but, the ldct diagnostic performance for acute appendicitis in radiology residents with variable training levels has not been well discussed.
منابع مشابه
Diagnostic Performance on Low Dose Computed Tomography For Acute Appendicitis Among Attending and Resident Radiologists
BACKGROUND Low-dose computed tomography (LDCT) techniques can reduce exposure to radiation. Several previous studies have shown that radiation dose reduction in LDCT does not decrease the diagnostic performance for appendicitis among attending radiologists. But, the LDCT diagnostic performance for acute appendicitis in radiology residents with variable training levels has not been well discusse...
متن کاملDiagnostic reliability of pediatric appendicitis score, ultrasound and low-dose computed tomography scan in children with suspected acute appendicitis
BACKGROUND Diagnosis of appendicitis in children is clinically challenging. Computed tomography (CT) is the gold standard for diagnosis; however, radiation exposure early in life is a concern with this technique. Therefore, in this study, we aimed to evaluate the diagnostic reliability of low-dose CT, pediatric appendicitis score (PAS), and abdominal ultrasound (US) in children with acute appen...
متن کاملDiagnostic Reference Level of Computed Tomography Examinations and Need for Dose Optimization in Ondo State, Nigeria
Introduction: The present study was conducted to obtain State diagnostic reference levels (DRLs) of five routine computed tomography (CT) examinations from two CT centers in Ondo State and to identify factors responsible for dose variation and escalation in these CT centers. Material and Methods: Acquisition parameters and CT dose indices wer...
متن کاملLOCAT (low-dose computed tomography for appendicitis trial) comparing clinical outcomes following low- vs standard-dose computed tomography as the first-line imaging test in adolescents and young adults with suspected acute appendicitis: study protocol for a randomized controlled trial
BACKGROUND Computed tomography is widely used to diagnose acute appendicitis. Many adolescents and young adults are exposed to the associated radiation. A recent single-institution trial has reported promising results for low-dose computed tomography; however, this technique has not yet been widely adopted. LOCAT (low-dose computed tomography for appendicitis trial), a multi-institution randomi...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملDose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiologyجلد ۱۳، شماره ۲، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023