tc-flsfcl provision for improvement of distribution system reliability by topsis based nsga-ii method
نویسندگان
چکیده
an approach for assignment of the optimal location and tap changer adjustment related to flux-lock type superconducting fault current limiters with tap changer (tc-flsfcl) is used in this paper by debating the reduction of fault current flowing from each device and enhancement of reliability varying with customer type in a distribution network connected with distribution generation (dg). tc-flsfcl is a flexible sfcl that it has some preference than previous sfcls. in this type of sfcl the current limiting characteristics are improved and the fault current limiting level during a fault period can be adjusted by controlling the current in third winding, which also made the magnetic field apply to the high-tc superconducting (htsc) element. three objective functions based on reliability index, reduction of fault current and number of installed tc-flsfcl is systematized and non-dominated sorting genetic algorithm-ii (nsga-ii) style is then formed in searching for best location and tuning of tap changer of tc-flsfcl to meet the fitness requirements. a decision-making procedure based on technique for order preference by similarity to ideal solution (topsis) is used for finding best compromise solution from the set of pareto-solutions obtained through nsga-ii. in a distribution network as bus 4 of roy billinton test system (rbts), comparative analysis of the results obtained from application of the resistive sfcl (rsfcl) and tc-flsfcl is presented. the results show that optimal placement of tc-flsfcl than rsfcl can improve reliability index and fault current reduction index with less number
منابع مشابه
TC-FLSFCL Provision for Improvement of Distribution System Reliability by TOPSIS based NSGA-II Method
An approach for assignment of the optimal location and tap changer adjustment related to flux-lock type superconducting fault current limiters with tap changer (TC-FLSFCL) is used in this paper by debating the reduction of fault current flowing from each device and enhancement of reliability varying with customer type in a distribution network connected with distribution generation (DG). TC-FLS...
متن کاملapplication of upfc based on svpwm for power quality improvement
در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...
15 صفحه اولDesign of Reliability Insurance Scheme Based on Utility Function for Improvement of Distribution Grid Reliability
The regulatory schemes currently used for reliability improvement have weaknesses in the provision of quality services based on the customers’ perspective. These schemes consider the average of the service as a criterion to incentivize or penalize the distribution system operators (DSOs). On the other hand, most DSOs do not differentiate electricity services at the customer level, due to the st...
متن کاملA Customer Oriented Approach for Distribution System Reliability Improvement using Optimal Distributed Generation and Switch Placement
The reliability of distribution networks is inherently low due to their radial nature, consequently distribution companies (DisCos) usually seek to improve the system reliability indices with the minimum possible investment cost. This can be known as system-oriented reliability planning (SORP). However, there can exist some customers that are not satisfied by their reliability determined by ado...
متن کاملA Scheduling Model for the Re-entrant Manufacturing System and Its Optimization by NSGA-II
In this study, a two-objective mixed-integer linear programming model (MILP) for multi-product re-entrant flow shop scheduling problem has been designed. As a result, two objectives are considered. One of them is maximization of the production rate and the other is the minimization of processing time. The system has m stations and can process several products in a moment. The re-entrant flow sho...
متن کاملNSGA-II-Based Multi-objective Mission Planning Method for Satellite Formation System
AbstrAct: This study proposes a non-dominated sorting genetic algorithm-II-based multi-objective optimization method to solve the multi-objective mission planning problem for satellite formation flying system which has the ability to obtain both digital elevation map and ground moving target indicator information at the same time when certain conditions are satisfied. The 2 objectives considere...