trans-cutaneous bilirubinometery versus serum bilirubin in neonatal jaundice

نویسندگان

manoochehr mahram department of pediatrics, children growth research center, qazvin university of medical science, qazvin, iran.

sonia oveisi department of community of medicine, metabolic diseases research center, qazvin university of medical sciences, qazvin, iran.

najmeh jaberi school of medicine, qazvin university of medical science, qazvin, iran.

چکیده

hyperbilirubinemia is a common problem in neonates and causes serious complications. thus, serial measurements of bilirubin should be done. this assessment is done through two methods of laboratory measurement in serum sample and transcutaneous bilirubinometer. this descriptive study compared transcutaneous bilirubin assessment and laboratory serum bilirubin. bilirubin level was assessed among 256 neonates admitted to the qods children’s hospital in qazvin- iran, because of neonatal indirect jaundice, through two methods of transcutaneous bilirubinometery from two sites of forehead and sternum and laboratory measurement of bilirubin in serum. the cases were non-hemolytic icteric term neonates weighing 2500 gram or more and had not received phototherapy or other treatments. neonates with hemolytic forms of jaundice, sepsis and suspicious to metabolic disorders were excluded. assessments by means of kj-8000 transcutaneous bilirubinometer from two sites of forehead and sternum and through laboratory measurement of serum bilirubin were registered and analyzed. the results of the current study showed that there was a correlation of 0.82 between serum bilirubin and transcutaneous forehead bilirubin assessment and for the used device sensitivity of 0.844; specificity of 0.842, youden index of 0.709 and shortest of 0.042 for a cut-off of 12.4 in bilirubin of participants. furthermore, likelihood ratio positive and negative (lr) were 5.665 and 0.164, respectively and diagnostic odds ratio (lr+/lr-) was 34.56. transcutaneous bilirubinometery can be considered as a reliable tool to assess bilirubin for the screening of neonatal jaundice in term neonates.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trans-Cutaneous Bilirubinometery versus Serum Bilirubin in Neonatal Jaundice.

Hyperbilirubinemia is a common problem in neonates and causes serious complications. Thus, serial measurements of bilirubin should be done. This assessment is done through two methods of laboratory measurement in serum sample and transcutaneous bilirubinometer. This descriptive study compared transcutaneous bilirubin assessment and laboratory serum bilirubin. Bilirubin level was assessed among ...

متن کامل

Comparing transcutaneous bilirubin versus serum bilirubin measurement using spectrophotometry for jaundice screening of full-term neonates

Background: Neonatal jaundice is an almost common problem among neonates that may cause complications such as kernicterus in severe cases. Since early diagnosis and proper treatment of neonatal jaundice is vital to prevent the related complications, it is necessary to check bilirubin before discharging the neonates. There are several evaluating and diagnostic methods to measure the level of bil...

متن کامل

Relationship between Neonatal Skin Bilirubin Level and Severe Jaundice with Maternal, Childbirth, and Neonatal Characteristics

Background: Neonatal jaundice is the most common cause of newborns' hospitalization. This study aimed to examine various maternal, childbirth, and neonatal factors affecting the neonatal skin bilirubin level and severe jaundice. Methods: This cross-sectional study was conducted on 1066 healthy neonates with a gestational age of 35 weeks or ov...

متن کامل

Bilirubin rebound after intensive phototherapy for neonatal jaundice.

This study was conducted to determine the incidence and magnitude of post-phototherapy bilirubin rebound in neonates. Subjects included inborn neonates needing phototherapy for hyperbilirubinemia. Standard guidelines were used to start and stop phototherapy. Rebound bilirubin was measured 24+/-6 h after stopping phototherapy. Significant bilirubin rebound (SBR) was defined as post-phototherapy ...

متن کامل

Unbound (free) bilirubin: improving the paradigm for evaluating neonatal jaundice.

BACKGROUND The serum or plasma total bilirubin concentration (B(T)) has long been the standard clinical laboratory test for evaluating neonatal jaundice, despite studies showing that B(T) correlates poorly with acute bilirubin encephalopathy (ABE) and its sequelae including death, classical kernicterus, or bilirubin-induced neurological dysfunction (BIND). The poor correlation between B(T) and ...

متن کامل

Serum bilirubin kinetics in intermittent phototherapy of physiological jaundice.

Thirty four term babies with physiological jaundice were subjected to continuous phototherapy and to two regimens of intermittent phototherapy. The difference in serum bilirubin kinetics between the three groups of treated babies was insignificant; a schedule of one in four hours of irradiation achieved the same treatment effect as continuous phototherapy.

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
acta medica iranica

جلد ۵۳، شماره ۱۲، صفحات ۷۶۴-۷۶۹

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023