findings of optical coherence tomography of retinal nerve fiber layer in two common types of multiple sclerosis

نویسندگان

gholamali yousefipour department of neurology sciences, clinical neurology research center, shiraz university of medical sciences, shiraz, iran.

zabihollah hashemzahi department of neurology sciences, clinical neurology research center, shiraz university of medical sciences, shiraz, iran.

masood yasemi department of ophthalmology, poostchi eye research center, shiraz university of medical sciences, shiraz, iran.

pegah jahani department of medicine, student research committee, shiraz university of medical sciences, shiraz, iran.

چکیده

multiple sclerosis (ms) is the most prevalent disease caused by the inflammatory demyelinating process that causes progressive nervous system degeneration over the time. optical coherence tomography (oct) is a non-invasive optical imaging technology, which can measure the thickness of retinal nerve fiber layer as well as the diameter of the macula. the purpose of the study is evaluation oct findings in two common types of multiple sclerosis. for doing the cross-sectional study, 63 patients with two prevalent types of multiple sclerosis (35 patients with relapse remitting multiple sclerosis (rrms) and 28 patients with secondary progressive multiple sclerosis (spms) were evaluated for 6 months. exclusion criteria of the study were a history of optic neuritis, suffering from diabetes mellitus, hypertension, ocular disease, and the presence of other neurologic degenerative diseases. then, the thickness of retinal nerve fiber layer (rnfl), as well as thickness and volume of the macula, were measured in the patients using oct technology. the disability rate of patients was evaluated according to expanded disability status scale (edss). finally, data was analyzed by means of spss software. overall, 35 patients with rrms (with mean age of 32.37+10.01, average disease period of 3.81+3.42 and mean edss of 1.84+0.45) and 28 patients with spms (with mean age of 39.21+9.33, average disease period of 11.32+5.87 and mean edss of 5.12+1.46) were assessed and compared in terms of retinal nerve fiber layer and size and thickness of macula. in all of these sections, the thicknesses were smaller in spms patients than patients with rrms. but, there was a significant difference in total thickness (81.82µm versus 96.03µm with p =0.04) and thickness of temporal sector (54.5 µm versus 69.34 µm with p =0.04) of retinal nerve fiber layer and macular size at the superior sector of external ring (1.48 mm³ versus 1.58 mm³ with p =0.03), and nasal sector of external ring surrounding macula (1.53 mm³ versus 1.66 mm³ with p =0.03). no significant correlation was found among rising disability and reduced thickness of macula and optic nervous layer. based on the study results, it can be said that oct is a useful method for showing axonal degeneration severity and evaluation of various drugs effects on the course of ms disease, and thus we can change drugs based on oct findings for achieving best results.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Findings of Optical Coherence Tomography of Retinal Nerve Fiber Layer in Two Common Types of Multiple Sclerosis.

Multiple sclerosis (MS) is the most prevalent disease caused by the inflammatory demyelinating process that causes progressive nervous system degeneration over the time. Optical Coherence Tomography (OCT) is a non-invasive optical imaging technology, which can measure the thickness of retinal nerve fiber layer as well as the diameter of the macula. The purpose of the study is evaluation OCT fin...

متن کامل

comparison of peripapillary retinal nerve fiber layer thickness measured by two different optical coherence tomography devices

purpose: to determine agreement between peripapillary retinal nerve fiber layer (rnfl) thickness measurements by two different spectral domain optical coherence tomography (sd-oct) machines. methods: both eyes of 89 subjects were evaluated using cirrus oct (carl zeiss meditec, inc. dublin, ca, usa) and topcon oct (3d oct 1000, topcon corporation, tokyo, japan). one eye was randomly selected in ...

متن کامل

Retinal nerve fiber layer evaluation in multiple sclerosis with spectral domain optical coherence tomography

PURPOSE Histopathologic studies have reported retinal nerve fiber layer (RNFL) thinning in various neurodegenerative diseases. Attempts to quantify this loss in vivo have relied on time-domain optical coherence tomography (TDOCT), which has low resolution and requires substantial interpolation of data for volume measurements. We hypothesized that the significantly higher resolution of spectral-...

متن کامل

Optical Coherence Tomography Retinal Nerve Fiber Analysis: A Measure of Axon Loss in Multiple Sclerosis

Objective to investigate whether optical coherence tomography (OCT) could demonstrate axonal loss through thinning of the retinal nerve fiber layer (RNFL) in multiple sclerosis (MS) patients. Furthermore, the degree of RNFL loss was compared in the different MS subgroups (with or without optic neuritis, affected or fellow eye, single episode or recurrent optic neuritis, relapsing remitting or p...

متن کامل

An investigation of the retinal nerve fibre layer in progressive multiple sclerosis using optical coherence tomography.

Axonal loss is thought to be the predominant cause of disability in progressive multiple sclerosis (MS). The retinal nerve fibre layer (RNFL) is composed largely of unmyelinated axons of retinal ganglion cells, and is accessible to study with optical coherence tomography (OCT), giving a measure of axonal loss. OCT measures of the RNFL thickness (RNFLT) and macular volume were studied in 23 pati...

متن کامل

Optical Coherence Tomography Findings in a Patient with Myelinated Retinal Nerve Fiber Layer

A 33-year-old man presented with low vision in his left eye. Best corrected visual acuity (OD: plano, OS: -7.5 diopters) was 20/20 in his right eye and counting fingers at 50 cm in the left eye. Relative afferent pupillary defect was 2+ in the left eye. Slit lamp examination was unremarkable in both eyes and intraocular pressure was within normal limits. Dilated fundus examination was normal in...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
acta medica iranica

جلد ۵۴، شماره ۶، صفحات ۳۸۲-۳۹۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023