analytical performance and quality control of a glucose monitor system

نویسندگان

aileen azari yam

peyman mohammadi torbati

چکیده

background and objective: the reliability and validity of monitors for self-monitoring of blood glucose are debated. we evaluated the analytical performance of accu-check active (boehringer mannheim, roche) which is one of the most commonly used monitors in iran. material and methods: we compared the monitor readings with the reference values by percentage of values within certain intervals of the reference method, regression analysis, and difference plot. we used operational process specification charts to determine the probability that different qc rules would detect an analytical error. in addition, we assessed the quality on the sigma scale. results: this meter met international organization for standardization’s criteria but not the american diabetes association’s stringent criteria. the monitor produced precise readings throughout the concentration range and results correlated closely with the reference method. the measured total error was 6.39% (less than allowable total error of 10%). the method reached 6 sigma at glucose levels of 6.66 and 18.87 mmol/l and a sigma of 3 to 4 at glucose level of 2.49. repeatability and intermediate precision were acceptable. discussion: we concluded that the overall performance of this instrument is reasonable but in hypoglycemic range, multiple control rules and control materials are required to assure the desired quality is achieved.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical Performance and Quality Control of a Glucose Monitor System

  Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...

متن کامل

performance of biological system and advanced oxidation processes (aop) treating antibiotic production industrial wastewater

در این مطالعه، عملکرد دو سیستم اکسیداسیون شیمیایی پیشرفته و یک سیستم بیولوژیکی برای حذف آموکسی سیلین در فاضلاب های سنتزیدر غلظت های مشابه با موارد صنعتی مورد بررسی قرار گرفته شدند. مطالعه انجام شده دارای سه بخش متفاوت اکسیداسیون با ازن و اشعه uv، اکسیداسیون با استفاده از نانو فتوکاتالیست tio2 و استفاده از بیوراکتور هوازی لجن فعال با جداکننده های فیزیکی می باشد. در هر بخش، متغیر های متفاوتی متنا...

15 صفحه اول

Using Shewhart p control charts of external quality-assurance program data to monitor analytical performance of a clinical chemistry laboratory.

We have investigated the application of Shewhart's p control charts in our external quality-assurance program to monitor the long-term performance of our laboratory's analytical quality. The p control charts have been able to detect long-term changes in our laboratory's analytical performance that would have been difficult to detect by more-conventional techniques. We have explored methods for ...

متن کامل

effect of seed priming and irrigation regimes on yield,yield components and quality of safflowers cultivars

این مطالعه در سال 1386-87 در آزمایشگاه و مزرعه پژوهشی دانشگاه صنعتی اصفهان به منظور تعیین مناسب ترین تیمار بذری و ارزیابی اثر پرایمینگ بر روی سه رقم گلرنگ تحت سه رژیم آبیاری انجام گرفت. برخی از مطالعات اثرات سودمند پرایمینگ بذر را بر روی گیاهان مختلف بررسی کرده اند اما در حال حاضر اطلاعات کمی در مورد خصوصیات مربوط به جوانه زنی، مراحل نموی، عملکرد و خصوصیات کمی و کیفی بذور تیمار شده ژنوتیپ های م...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of pathology

ناشر: iranian society of pathology

ISSN 1735-5303

دوره 6

شماره 1 2011

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023