distributed generation voltage synchronization when the state changes from islanding to grid connected
نویسندگان
چکیده
abstract: in this paper a control scheme for grid-connected operation mode and the island state of distributed generation is presented. in normal conditions, every inverter dg system in micro-grids to supply a preset power, normally operate in a constant current control mode. when micro-grids removed from the network, dg inverter of each system must recognize the island and change position to voltage control mode. in this situation micro-grids supply the fixed voltage to local load. in this paper, a synchronization algorithm is provided for reconnection to the network. the results of the simulation dg, network controllers, and the islanding is provided in matlab simulink.
منابع مشابه
anti-islanding protection of grid connected distributed generators
a critical protection requirement for grid connected distributed generators (dg) is anti-islanding protection. in this paper, a new islanding detection method for any possible network loading is proposed based on utilizing and combining various system parameter indices. in order to secure the detection of islanding, eight intentional disturbances are imposed to the system under study in which t...
متن کاملControl of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids
In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...
متن کاملRadial Basis Neural Network Based Islanding Detection in Distributed Generation
This article presents a Radial Basis Neural Network (RBNN) based islanding detection technique. Islanding detection and prevention is a mandatory requirement for grid-connected distributed generation (DG) systems. Several methods based on passive and active detection scheme have been proposed. While passive schemes have a large non detection zone (NDZ), concern has been raised on active method ...
متن کاملInvestigation of the Effect of Synchronization Techniques on the Stability of Grid-Connected Photovoltaic Systems
Abstract: Due to the increasing use of microgrids, investigation of their stability is of special interest. One of the disadvantages of an inverter-based distribution unit is that at any given time, phase and frequency information at the point of common coupling (PCC) is required that affected the stability. The synchronization techniques include synchronous reference frame phase-locked loop (S...
متن کاملSliding Mode Control of a Grid-Connected Distributed Generation Unit under Unbalanced Voltage Conditions
The increasing presence of inverter-based distributed generation (DG) units in distribution networks (DNs) requires control methods that achieve high performance not only during normal operating conditions, but also under unbalanced conditions. With a high probability, a type of voltage unbalance in DNs is unequal three-phase voltage magnitudes at the fundamental system frequency. This can occu...
متن کاملVoltage Control Scheme with Distributed Generation and Grid Connected Converter in a DC Microgrid
Direct Current (DC) microgrids are expected to become larger due to the rapid growth of DC energy sources and power loads. As the scale of the system expends, the importance of voltage control will be increased to operate power systems stably. Many studies have been performed on voltage control methods in a DC microgrid, but most of them focused only on a small scale microgrid, such as a buildi...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
تحقیقات نوین در برقجلد ۲، شماره ۱، صفحات ۵۱-۵۸
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023