patient dose in routine x-ray examinations in yazd state
نویسندگان
چکیده
background: medical x-rays are the largest man-made source of public exposure to ionizing radiation. it is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. materials and methods: the entrance skin exposure (ese) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. the eses were measured by unfors dosimeter for five common types (12 projections) of x-ray procedures in standard man for the 18 public hospitals of yazd province. results: the median, 3rd quartile, minimum, and maximum values of each eses distributions are reported. the 12 histograms are presented showing wide distribution of measured ese in each examination. the survey results are compared with guide levels that reported by crcpd or nrpb. the sum of eses measurements such as in skull, th-spine and l-spine are projection out of the guide levels. one of reasons of the wide eses distribution is miss unique role in selection of techniques for the same procedure and same patient size by operators in each center and even for one x-ray machine. conclusion: the findings support the importance of the on-going quality assurance program to ensure doses are kept to a level consistence with optimum imaging quality. iran . j. radiat. res., 2004 1(4): 199-204
منابع مشابه
Patient dose in routine X-ray examinations in Yazd state
Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...
متن کاملEntrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals
Background: There is not any report on the radiation doses received by patients in diagnostic radiology sections in hospitals under control of Chaharmahal and Bakhtiari Medical Sciences University, in the south west of Iran. Objectives: The aim of this study is measurement of entrance surface doses (ESD) for the most routine types of X-ray procedures in radiology centers as part of ongoing d...
متن کاملRadiation Dose Measurements in Routine X ray Examinations
The aim of current study was to evaluate patient's radiation dose in routine X-ray examinations in Omdurman teaching hospital Sudan.110 patients was examined (134) radiographs in two X-ray rooms. Entrance surface doses (ESDs) were calculated from patient exposure parameters using DosCal software. The mean ESD for the chest, AP abdomen, AP pelvis, thoracic spine AP, lateral lumber spine , antero...
متن کاملPatient dose resulting from CT examinations in Yazd, Iran
Background: With the introduction of computed tomography in diagnostic radiology a new and fundamentally different imaging modality has become available. Meanwhile, it is clear that the absorbed doses by the patients during CT were relatively high in comparison with those of other diagnostic radiology techniques. The aim of this survey was to determine the average absorbed dose in Yazd provin...
متن کاملentrance surface dose measurements for routine x-ray examinations in chaharmahal and bakhtiari hospitals
background: there is not any report on the radiation doses received by patients in diagnostic radiology sections in hospitals under control of chaharmahal and bakhtiari medical sciences university, in the south west of iran. objectives: the aim of this study is measurement of entrance surface doses (esd) for the most routine types of x-ray procedures in radiology centers as part of ongoing dose...
متن کاملDiagnostic reference levels (DRLs) for routine X-ray examinations in Lorestan province, Iran
Background: In diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. Firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. Secondly estimates of the absorbed dose to tissue and organs in the patients. Materials and Methods: A total of 2382 patients were studied t...