dosimetry of 188re and 186re sources based on monte carlo calculations for endovascular brachytherapy after balloon angioplasty
نویسندگان
چکیده
background: recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 gy can reduce rate of restenosis in patients who have undergone an angioplasty. the use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. materials and methods: the monte carlo n-particle transport code (mcnp4b) was used to calculate the dose rate distribution in the tissue equivalent material around the 188re and 186re liquid sources. schematic of medical internal radiation dose (mird) for homogeneous distribution of radio-nuclide in a lesion was used for mean organ absorbed dose calculation due to the internal distribution. results: results indicate that 188re liquid with 100 mci/ml and 186re liquid with 250 mci/ml can deliver desired dose in the vessel wall to reduce restenosis. the dose ratio in depth of 0.5 mm to surface of vessel wall for 188re and 186re were 40% and 18%, respectively. therefore in case of 186re, there is a little non-uniformity with respect to the 188re case. the delivery of form 186re dose to normal tissue around target tissue is less than 188re. conclusion: use of the monte carlo simulation with 188re-dtpa and 186re-dtpa for intra-vascular brachytherapy is a feasible method of delivering a desired dose to the vessel walls. although188re-dtpa delivers the desired dose to the target tissue with lower radioactive concentration (mci/ml), but with the use of 186re-dtpa, the delivery dose to normal tissue around the target tissue is less. iran . j. radiat. res., 2004 2 (2): 89-95
منابع مشابه
Dosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty
Background: Recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 Gy can reduce rate of restenosis in patients who have undergone an angioplasty. The use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. Materials and Methods: The Monte Carlo N-particle Transport Code (MCNP4b) was used...
متن کاملDosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty
R ecent pre-clinical and clinical studies indicate that irradiation within the dose range of 15 to 30 Gy can reduce the rate of restenosis in patients who have undergone an angioplasty (Nath 1999, King 1998). Several delivery systems of intravascular brachytherapy have been developed to deliver doses within this rang with minimal normal tissue toxicity. One of the possible intravascular irradia...
متن کاملComparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations
Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...
متن کاملRadial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations
Background: The Monte Carlo (MC) method is not only used for dose calculations around brachytherapy sources but also for benchmarking treatment planning systems (TPS) calculations. Materials and Methods: Three 60Co sources of GZP6 brachytherapy unit were simulated using MCNP4C MC Code. The radial dose functions were calculated by MC method and GZP6 TPS and were compared. Results: There was a go...
متن کاملcomparison of dosimetry parameters of two commercially available iodine brachytherapy seeds using monte carlo calculations
background: iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. dosimetric parameters of brachytherapy sources should be determined according to aapm tg-43u1 recommendations before clinical use. monte carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. materials and methods: dosimetric parameters (dos...
متن کاملEGSnrc Monte Carlo calculated dosimetry parameters for Ir and Yb brachytherapy sources
This study presents the results of EGSnrc Monte Carlo calculations of the dose distribution surrounding a high dose rate Yb brachytherapy source and 14 high dose rate and pulsed dose rate Ir brachytherapy sources. Energy-weighted spectra of emitted photons, a full set of TG-43 dosimetry parameters, along-away dose tables, and a description of the materials and geometry used for each source are ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiation researchجلد ۲، شماره ۲، صفحات ۸۹-۹۵
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023