ion-pair-based dispersive liquid liquid microextraction combined with flame atomic absorption spectrometry for a sensitive determination of trace amounts of nickel in food samples

نویسندگان

soleiman bahar

چکیده

in this study, a sensitive method of dispersive liquid phase microextraction based on ion-pair combined with the flame atomic absorption spectrometry was proposed for the determination of trace ni(ii) using aliquat 336-chloride as ion pair agent. several factors which have effect on  the microextraction efficiency of ni(ii), such as ph, extraction and dispersive solvent type and their volume, concentration of the aliquat 336-chloride, extraction time were investigated and the optimized experimental conditions were established. after extraction, the enrichment factor was 47. the detection limit of the method was 8.0 µg l-1 and the relative standard deviation for eight determinations of 100 µg l-1 ni(ii) was 2.1 %. the results for the determination of ni(ii) in food samples (black tea, lettuce, parsley and carrot) have demonstrated the accuracy, recovery and applicability of the proposed method.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ion Pair Dispersive Liquid-Liquid Microextraction for the Determination of Trace Amounts of Copper(II) in Soil, Multivitamin Tablet, Tea and Water Samples Using Flame Atomic Absorption Spectrometry

Ion pair dispersive liquid- liquid microextraction (IP-DLLME) method combined with flame atomic absorption spectrometry was proposed for the determination of trace amounts of copper(II). By using pyrocatechol violet as chelating agent and cetyltrimethyl ammonium bromide as an ion pairing agent, the trace amount of copper(II) was extracted in chloroform. The factors influencing the formation cop...

متن کامل

Preconcentration and determination of palladium water samples by ionic liquid - dispersive liquid liquid microextraction combined with flame atomic absorption spectrometry

A simple, rapid and efficient dispersive liquid–liquid microextraction by use of ionic liquid (IL-DLLME)method, followed by flame atomic absorption spectrometry (FAAS) was developed for the preconcentrationand determination of palladium in water samples. In this method, an appropriate mixture of acetone and octylmethyl imidazolium hexafluorophosphate was injected rapidly into the aqueous sample...

متن کامل

Dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry for determination trace amount of cobalt in water samples

An efficient, rapid, simple, and highly selective dispersive liquid–liquid microextraction basedon solidification of floating organic drop (DLLME-SFOD), combined with flame atomicabsorption spectrometry was developed for preconcentration and determination of trace amountsof cobalt in water samples. In this method, an appropriate mixture of acetone and1-undecanol was injected rapidly into the aq...

متن کامل

Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop Combined with Flame Atomic Absorption Spectrometry for Preconcentration and Determination of Thallium(III) in Water Samples

Dispersive Liquid-Liquid MicroExtraction technique based on Solidification of a Floating Organic drop (DLLME-SFO) combined with flame atomic absorption spectrometry was developed for determination of thallium in water sample. An appropriate mixture of acetone and 1-undecanol was rapidly injected into an aqueous sample containing TlCl4- which forms an ion pair with bril...

متن کامل

Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Combined with Flame Atomic Absorption Spectrometry for Determination of Silver in Water Samples

The widespread use of silver compounds and silvercontaining procedures in industry, medicine, jewellery, cloud seeding and in disinfection of drinking water has resulted in an increasing silver content in environmental samples. Silver impregnated filters are used in water disinfection, while silver concentrations up to 200 μg L are permitted for antimicrobial activities for human health. Silver...

متن کامل

dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry for determination trace amount of cobalt in water samples

an efficient, rapid, simple, and highly selective dispersive liquid–liquid microextraction basedon solidification of floating organic drop (dllme-sfod), combined with flame atomicabsorption spectrometry was developed for preconcentration and determination of trace amountsof cobalt in water samples. in this method, an appropriate mixture of acetone and1-undecanol was injected rapidly into the aq...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of analytical chemistry

ناشر: payame noor university, iran

ISSN 2383-2207

دوره 2

شماره 1 2015

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023