maternal expectations and experiences of labor analgesia with nitrous oxide
نویسندگان
چکیده
background although there are various methods for painless delivery such as using entonox gas, most of the people are unfamiliar or concerned about it yet. objectives the purpose of this study was to assess maternal expectations and experience of labor analgesia with nitrous oxide. patients and methods in a clinical trial study, 98 pregnant women in active phase of delivery were studied randomly in two groups (intervention group = 49, control group = 49) after obtaining written consent. efficacy, experience satisfaction, and also expectation of pregnant women about entonox gas in two groups were compared, likewise in intervention group before and after using entonox gas. results most of the pregnant women receiving entonox gas had less labor pain (91.8%), and were satisfied with it (98%). the severity of pain in the most of entonox user was moderate level (46.94%), while for the control group it was severe (55.10%) which was significant, 40.82% of the mother in entonox group had a severe pain and 10.20% had a very severe pain, whereas in the control group (55.10%) of the mother had a severe pain and 26.53% of the had very severe pain (p = 0.004). efficacy of labor pain was in moderate level in most cases. 49% of pregnant women receiving gas described their experience as a good and excellent. 80.9% indicated that they will request the mentioned painless method in the future. the amount of suffering from gas side effects was mild in most patients of intervention group (63%). expectations of the majority of pregnant women in intervention group (before receiving gas) and control group for painless delivery were weak (65.3%, 40.9%). the percentage of positive expectations had increased after receiving entonox gas (p = 0.01). there was a difference between the expectations of intervention group receiving entonox gas and control group (p = 0.001). positive expectations were more in intervention group than the control group. most differences of expectations in intervention group before and after receiving the gas were about higher efficacy (p = 0.001), more satisfaction (p = 0.001), fewer complications (p = 0.001), information about gas as painless delivery method (p = 0.02), and also previous experience of intolerable labor pain (p = 0.04). conclusions this study has shown that using entonox gas caused less labor pain, favorable expectations and experiences and also more maternal satisfaction.
منابع مشابه
Maternal Expectations and Experiences of Labor Analgesia With Nitrous Oxide
BACKGROUND Although there are various methods for painless delivery such as using entonox gas, most of the people are unfamiliar or concerned about it yet. OBJECTIVES The purpose of this study was to assess maternal expectations and experience of labor analgesia with nitrous oxide. PATIENTS AND METHODS In a clinical trial study, 98 pregnant women in active phase of delivery were studied ran...
متن کاملSafety and risks of nitrous oxide labor analgesia: a review.
INTRODUCTION This review of the safety and risks of nitrous oxide (N(2) O) labor analgesia presents results of a search for evidence of its effects on labor, the mother, the fetus, the neonate, breastfeeding, and maternal-infant bonding. Concerns about apoptotic damage to the brains of immature mammals exposed to high doses of N(2) O during late gestation, possible cardiovascular risks from hyp...
متن کاملNitrous oxide as labor analgesia: clinical implications for nurses.
A new interest in self-administered nitrous oxide for labor analgesia has emerged in recent years in the United States. It has been used widely in Europe for decades, with favorable results. The American College of Nurse-Midwives published a position statement in 2010 supporting the practice of self-administered nitrous oxide as an additional analgesia choice for laboring women. Recent literatu...
متن کاملNitrous Oxide ht , Earljt Labor
Buckground: Intermlttent sclf-adnrhrlstered nltrous oxlde has long had wldesprcad use as an analgeslc ln labor, but lts e{ficacy has not been adequately establlshed. Questlons about Its efrect on maternal oxygenatlon betwecn labor contractlons also have been ralse<!. Mctbodst Twenty-slx wornen were recrulted to partlclpate in a randomlzed, double-bllnd, cross-over, placebo.controlled study to a...
متن کاملIntrathecal Analgesia Versus Non-analgesia in Labor on Maternal and Neonatal Outcomes
Aims: Spinal analgesia is the most common method that provides pain relief during labor and controversy exists about its effect on the maternal and fetal among the women. This study was conducted to determine the effect of intrathecal analgesia (ITA) on perineal laceration, duration of the first, second, and third stage of labor, and Apgar score. Materials & Methods: Fifty primipara parturien...
متن کاملThe levels of nitrous oxide analgesia.
The literature on the effects of various levels of nitrous oxide is reviewed. The rapid uptake and excretion of the gas facilitates the recognition of four levels or zones depending upon the concentration used. In the lightest level of nitrous oxide, Zone 1, moderate analgesia is present with few side effects. In Zone 2 psychological side effects of dissociation are present in addition to more ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian red crescent medical journalجلد ۱۴، شماره ۱۲، صفحات ۷۹۲-۷
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023