accuracy of working length determination in root canal treatment using different algorithms

نویسندگان

sanam mirbeygi department of oral and maxilofacial radiology, shahid sadoughi university of medical sciences, yazd, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی شهید صدوقی یزد (shahid sadooghi university of medical sciences)

maryam kazemipoor department of endodontics, shahid sadoughi university of medical sciences, yazd, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی شهید صدوقی یزد (shahid sadooghi university of medical sciences)

sahar ghane department of oral and maxillofacial rafiology, rafsanjan university of medical science, rafsanjan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی رفسنجان (rafsanjan university of medical sciences)

simin shafiei department of oral and maxilofacial radiology, shahid sadoughi university of medical sciences, yazd, ir iran; department of oral and maxilofacial radiology, school of dentistry, shahid sadoughi university of medical sciences, emam st. dahe fajr blv., yazd, ir iran. tel: +98-3536255881-4; +98-9126887642, fax: +98-3536250344سازمان اصلی تایید شده: دانشگاه علوم پزشکی شهید صدوقی یزد (shahid sadooghi university of medical sciences)

چکیده

conclusions according to the results of this study, the accuracy of the file length in improved digital images showed no significant difference in comparison with the actual file length. materials and methods using an analytical-diagnostic method, an access cavity was prepared in 36 mandibular and maxillary premolar teeth. a file # 15 was inserted into the canal of each tooth until the tip of the file was observed, then the files were retracted 0.5 mm. the teeth were then placed in an acrylic block, and finally, a radiograph was taken of the blocks. thereafter, the file in each canal was taken out and measured using a digital caliper. the obtained measurement was the real length of the file. the saved images underwent modifications using different algorithms of image processing. the working length was observed on a monitor under standard conditions. data were analyzed by t- test using spss (ver. 17). background determination of working length has great significance in root canal treatments. for this purpose, analog radiography has been replaced by digital radiography. despite numerous studies, there is still no accurate information about the resolution of these images. results based on the findings of this study, no significant difference was observed between the main image, the images processed with the emboss, enhancement, sharpen, and negative algorithms, and the actual file size regarding the means of error. none of the indices had a statistically significant difference with the actual file length (p > 0.05). objectives the aim of this study was to assess the accuracy of working length determination in root canal treatment using different algorithms in digital radiography.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiographic versus electronic root canal working length determination.

PURPOSE The aim of this ex vivo study was to compare the accuracy of radiographic and electronic root canal length determination methods, compared with actual root canal length obtained with stereomicroscope. MATERIALS AND METHODS Thirty extracted single-rooted permanent teeth were used for this study. After access preparation, actual length (AL) of the root canal were determined for each too...

متن کامل

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...

متن کامل

In vivo accuracy of conventional and digital radiographic methods in confirming root canal working length determination by Root ZX

OBJECTIVES To compare, in vivo, the accuracy of conventional and digital radiographic methods in determining root canal working length. MATERIAL AND METHODS Twenty-five maxillary incisor or canine teeth from 22 patients were used in this study. Considering the preoperative radiographs as the baseline, a 25 K file was inserted into the root canal to the point where the Root ZX electronic apex ...

متن کامل

Accuracy of Different Methods of Working Length Determination in Endodontics

Background: Accurate assessment of the working length determines the success and prognosis of endodontic treatment. There are no systematic reviews comparing the accuracy of different methods of working length determination in endodontics Aim: To evaluate clinical studies on the accuracy of different methods used for working length determination in endodontics. Search strategy: Search was condu...

متن کامل

Comparison between Rvg and Electronic Working Length Determination in Root Canal Treatment in Vivo Study

Objective: The aim of this study was to compare the diagnostic efficacy of an electronic apex locator (EAL) and radiovisigraphy (RVG) in working length (WL) determination. Materials and Methods: This study was performed on Single-rooted maxillary/mandibular teeth requiring root canal treatment. After administration of local anesthesia, the teeth were isolated and the pulp cavities were accessed...

متن کامل

Accuracy of Working Length Determination using NovApex and Root-ZX Apex Locators: An in vitro Study.

INTRODUCTION This ex vivo study evaluated the accuracy of the Root-ZX electronic apex locator (EAL) (J. Morita, Tokyo, Japan) and the NovApex (Forum Technologies, Rishon Lezion, Israel) in determining the working length (WL) during endodontic treatment. MATERIALS AND METHODS Forty extracted single-rooted human teeth were selected for this study. The actual WL was measured with visual techniqu...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
avicenna journal of dental research

جلد ۸، شماره ۲، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023