evaluation of keratoconus correction by ferrara intracorneal ring segments
نویسندگان
چکیده
background and objective: evaluation of the results, safety, and stability of ferrara intracorneal ring segment (ficrs) implantation for keratoconus correction (age range was 24.39±8.32 years). materials and methods: in this clinical trial study, 64 eyes of 57 patients with keratoconus and clear cornea that had ficrs implantation were studied. uncorrected visual acuity (ucva), best-spectacle corrected visual acuity (bscva), refractive errors, and corneal data from orb scan ii, and complications were analyzed. results: the follow-up was 18 months ± 6.45 (sd), the ucva improved from 1.14 logarithm of the minimum angle of resolution (log mar) ± 0.53 (sd) to 0.48 og mar ± 0.44 (sd) (p≤ 0.001) and the bscva improved from 0.44 log mar ± 0.40 (sd) to 0.23 log mar ± 0.19 (sd) (p≤ 0.001). improvement of main outcome measures were as follows: 4.90 diopter (d) ± 3.33 (sd) for spherical equivalent (p≤ 0.001), 4.16 d ±3.24 (sd) for spherical refractive error (p≤ 0.001), 1.49±2.31 (sd) for cylindrical refractive error (p≤ 0.001). corneal topography showed more improvement of corneal uniformity and irregular astigmatism. minimum and maximum central corneal powers decreased 1.75 d±5.94 (sd) (p≤ 0.03) and 4.75 d±3.33 (sd) (p≤ 0.001), respectively. significant decrease in anterior corneal curvature and posterior best-fit sphere curvature were observed. segment extrusion one eye (16%), superficial position 1 eye (1.6%), and infectin in 5 eyes (7.8%) had occurred. conclusion: during 18 months, ficrs implantation improved both ucva and bscva, however, it reduced corneal steepening and astigmatism. whereas, increased topographic regularity. ficrs implantation was a safe procedure that had led to stable results. this procedure prevented or delayed corneal graft in many cases.
منابع مشابه
Ferrara intracorneal ring segments for keratoconus.
PURPOSE To assess the outcome of Ferrara intracorneal ring segments for keratoconus. SETTING Private practice and university hospital, Porto Alegre, Brazil. METHODS In this retrospective noncomparative interventional case series, 51 keratoconus eyes of 47 patients that had Ferrara intracorneal ring segment implantation were reviewed. Uncorrected visual acuity (UCVA), best spectacle-correcte...
متن کاملferrara intrastromal corneal ring segments in keratoconus
purpose: to evaluate the efficacy and safety of ferrara intra-stromal corneal ring (fiscr) segments for keratoconus. methods: the study was performed on 57 eyes of 44 patients with keratoconus and clear cornea who were contact lens intolerant. subjects underwent complete ophthalmic examination before surgery. objective and subjective refraction achieving the best visual acuity was used to deter...
متن کاملThe use of intracorneal ring segments in keratoconus
Keratoconus is a corneal degeneration that usually appears during puberty and may seriously deteriorate the quality of life of the patients. This corneal disease is today the first indication of corneal transplantation in young patients. Until the last decade of the XX century, keratoplasty procedures were the only alternative to treat this pathological condition. In the beginning of the XXI ce...
متن کاملIntacs Intracorneal Ring Segments Complications in Patients Suffering from Keratoconus
Intacs, intrastromal corneal rings are widely used to reduce myopia, astigmatism, keratometry readings and high order aberrations in patients suffering from keratoconus, almost 15 years have passed from the first procedure which was performed in the eye of a patient with unsatisfactory visual acuity and contact lenses intolerance. Many publications including book chapters, retrospective studies...
متن کاملContact lenses fitting after intracorneal ring segments implantation in keratoconus.
PURPOSE Evaluate contact lenses fitting after intracorneal ring implantation for keratoconus, its visual acuity and comfort. METHODS Retrospective study of patients undergoing contact lenses fitting, after intracorneal ring for keratoconus. The criterion for contact lens fitting was unsatisfactory visual acuity with spectacle correction as referred by the patients. All patients were intoleran...
متن کاملTomographic Findings After Implantation of Ferrara Intrastromal Corneal Ring Segments in Keratoconus.
PURPOSE To analyze and compare changes to the anterior and posterior corneal surfaces after Ferrara intracorneal ring segment (ICRS) (AJL, Boecillo, Spain) implantation and to correlate those changes with visual outcomes. METHODS This retrospective case series study comprised consecutive patients with keratoconus implanted with the Ferrara ICRS. Computed tomography scans of the two corneal su...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دانشور پزشکیجلد ۱۶، شماره ۸۲، صفحات ۴۵-۵۲
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023