left ventricular volume and function assessment: a comparison study between echocardiography and ventriculography

نویسندگان

hoorak poorzand atherosclerosis prevention research center, school of medicine, imam reza hospital, mashhad university of medical sciences, mashhad, ir iran

alireza abdollahi atherosclerosis prevention research center, school of medicine, imam reza hospital, mashhad university of medical sciences, mashhad, ir iran; atherosclerosis prevention research center, school of medicine, imam reza hospital, mashhad university of medical sciences, mashhad, ir iran. tel: +98-9153113595, fax: +98-5118544504

mostafa sajadian mashhad university of medical sciences, mashhad, ir iran

toktam moghiman atherosclerosis prevention research center, school of medicine, imam reza hospital, mashhad university of medical sciences, mashhad, ir iran

چکیده

conclusions despite the widespread use of 2d lvef and its good agreement with ventriculography, strain analysis seems to be more reliable as a quantitative tool for ventricular assessment. results the lvef values obtained by the two methods of ventriculography and echocardiography were not significantly different. the highest correlation regarding the echocardiographic lvef was obtained in the angiographic right anterior oblique view (p < 0.001, r = 0.95). there was a good agreement as regards the biplane lvef between 2d echocardiography and ventriculography (-0.5 ± 13.27; ci of 95%). the gls showed a significant correlation with the estimated ef in both methods, the highest being with the biplane simpson method (r = -0.84; p < 0.001). linear regression was used to obtain the formula for estimating the 2d lvef from the gls [lvef = 2.53 (gls) + 10.48]. the gls values ≥ -21.7% and≤ -11.7% were consistent with normal and severe global lv systolic dysfunction, respectively. the inter- and intra-observer agreement was more evident in the gls measurement rather than in the lvef. objectives this study was aimed at comparing the lvef and lv volumes obtained by the two methods of catheterization and two-dimensional (2d) echocardiography (available in our institution) and assessing the correlation between the lvef and the gls. patients and methods in this cross-sectional study, 45 patients were recruited from coronary angiography candidates. the patients underwent echocardiography immediately before catheterization. the lvef and lv volumes were measured via echocardiography using the apical four- and two chamber-views. the gls was calculated through the automated functional imaging algorithm. left ventriculography was performed by calculating the lvef in the right and left oblique views. background the left ventricular ejection fraction (lvef) measurement is a common tool for evaluating the lv systolic function. the application of the global longitudinal systolic strain (gls) parameter in the assessment of the myocardial function has also received special attention recently.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography

Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...

متن کامل

Comparison between Radionuclide Ventriculography and Echocardiography for Quantification of Left Ventricular Systolic Function in Rats Exposed to Doxorubicin

BACKGROUND Radionuclide ventriculography (RV) is a validated method to evaluate the left ventricular systolic function (LVSF) in small rodents. However, no prior study has compared the results of RV with those obtained by other imaging methods in this context. OBJECTIVES To compare the results of LVSF obtained by RV and echocardiography (ECHO) in an experimental model of cardiotoxicity due to...

متن کامل

The effect of ventricular pacing on measurements of left ventricular function: a comparison between echocardiographic methods and with radionuclide ventriculography.

AIMS Different methods exist for measuring left ventricular function echocardiographically; each may be error prone due to the abnormal pattern of ventricular activation during pacing. METHODS AND RESULTS Echocardiography was undertaken on 307 patients with permanent pacemakers; a subset of 57 underwent radionuclide ventriculography. Intrinsic and paced beats were analysed for left ventricula...

متن کامل

assessment of deep word knowledge in elementary and advanced iranian efl learners: a comparison of selective and productive wat tasks

testing plays a vital role in any language teaching program. it allows teachers and stakeholders, including program administrators, parents, admissions officers and prospective employers to be assured that the learners are progressing according to an accepted standard (douglas, 2010). the problems currently facing language testers have both practical and theoretical implications but the first i...

ECHOCARDIOGRAPHY ASSESSMENT OF SYSTOLIC FUNCTION IN DIFFERENT LEFT vENTRICULAR GEOMETRIES

Congenital heart diseases (CHD) appear as a large variety of anomalies with different ventricular shapes, sizes and haemodynamics . Reliable assessment of ventricular function in children with complex cHd, such as univentricular heart or after a Fontan operation, is difficult, as the majority of echocardiographic (ECHO) parameters rely on geometric assumptions or haemodynamic factors . A number...

متن کامل

Assessment of left ventricular function by three-dimensional echocardiography

Accurate determination of LV volume, ejection fraction and segmental wall motion abnormalities is important for clinical decision-making and follow-up assessment. Currently, echocardiography is the most common used method to obtain this information. Three-dimensional echocardiography has shown to be an accurate and reproducible method for LV quantitation, mainly by avoiding the use of geometric...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
archives of cardiovascular imaging

جلد ۲، شماره ۳، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023