comparison of blood glucose values using two glucose meters and standard laboratory method in hospitalized patients in a teaching hospital

نویسندگان

shima aghakachoei pharm. d candidate, school of pharmacy and pharmaceutical sciences, isfahan university of medical sciences, isfahan, iran

amirh zargarzadeh assistant professor, department of clinical pharmacy and pharmacy practice, school of pharmacy and pharmaceutical sciences, isfahan university of medical sciences, isfahan, iran

masoud amini professor, department of internal medicine, school of medicine, isfahan university of medical sciences, isfahan, iran

چکیده

background : diabetes mellitus is a chronic disease with a worldwide prevalence and its complications can be prevented with close monitoring of blood glucose. quality of blood glucose monitoring utilizing glucometers in iranian hospitalized patients has not been well published in the literature. we evaluated the accuracy and consistency of the results of two devices compared with the standard laboratory method used for measuring glucose levels in a teaching hospital. methods: in this study 100 patients with the average age of 57.5 ±17.7 years were randomly selected from 19 wards and their blood glucose were simultaneously measured using accu-chek active®(1) and cleverchek®(2) (commonly used in the wards) and the conventional laboratory method. calibration was performed on both devices. results : absolute mean difference of the devices 1 and 2 from the laboratory values were 24.3±2.4,and 38.5±4.5, respectively (p: 0.003). correlation coefficient of the obtained values by glucometers1 and 2 with lab, were 0.82 and 0.52, respectively. calibration of the devices showed that device 1 was the most consistent device with the laboratory values, and pearson correlation coefficient between the obtained values as a result of four reiterations for each sample in each device showed that the highest coefficient belonged to the device 1 and the least belonged to the device 2 used in the ear, nose, and throat departments. conclusion: the device 2 used in different wards of the hospital must be calibrated periodically. furthermore, the device 1 generated closest results to the ones obtained through the laboratory.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...

متن کامل

Blood glucose monitoring in hospitalized patients.

accurate and more reliable than older glucometers [9]. In Israel, the National Diabetes Council has recommended the use of these institutional glucometers to the Ministry of Health, noting that they facilitate diabetes care and improve glucose homeostasis during the hospitalization of diabetic patients. The main purpose of implementing projects such as the Program for the Treatment of the Hospi...

متن کامل

Accuracy of blood-glucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: systematic review

INTRODUCTION Glucose control to prevent both hyperglycemia and hypoglycemia is important in an intensive care unit. Arterial blood gas analyzers and glucose meters are commonly used to measure blood-glucose concentration in an intensive care unit; however, their accuracies are still unclear. METHODS We performed a systematic literature search (January 1, 2001, to August 31, 2012) to find clin...

متن کامل

assessment of deep word knowledge in elementary and advanced iranian efl learners: a comparison of selective and productive wat tasks

testing plays a vital role in any language teaching program. it allows teachers and stakeholders, including program administrators, parents, admissions officers and prospective employers to be assured that the learners are progressing according to an accepted standard (douglas, 2010). the problems currently facing language testers have both practical and theoretical implications but the first i...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of pharmaceutical care

جلد ۲، شماره ۱، صفحات ۱۵-۲۱

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023