optimal glycemic and hemoglobin a1c thresholds for diagnosing diabetes based on prevalence of retinopathy in an iranian population

نویسندگان

naser samadi aidenloo department of ophthalmology, urmia university of medical sciences, urmia, ir iran

alireza mehdizadeh department of endocrinology, urmia university of medical sciences, urmia, ir iran; department of endocrinology, urmia university of medical sciences, urmia, ir iran. tel: +98-9143407326, fax: +98-4433469935

neda valizadeh department of endocrinology, urmia university of medical sciences, urmia, ir iran

mohammad abbaszadeh department of ophthalmology, urmia university of medical sciences, urmia, ir iran

چکیده

background the use of glycemic thresholds for diabetes diagnosis is controversial. however, no information is available regarding glycemic and glycated hemoglobin (hba1c) thresholds for detecting diabetic retinopathy (dr) in the iranian population. objectives the main purpose of the current investigation was to examine the association of fasting plasma glucose (fpg) and hba1c levels with diabetic retinopathy (dr), and to determine the relevant cut-off levels in an iranian population. patients and methods this cross-sectional, population-based study was performed during 2012-2013 in urmia, the capital of west azerbaijan province, iran. the subjects were 3,010 iranians aged 40-81 years. the fpg levels were determined using the glucose oxidase method whereas, the hba1c values were measured using a standardized assay by high performance liquid chromatography. dr was evaluated by an examination of the fundus photograph of each eye. the photographs were graded according to the international clinical diabetic retinopathy disease severity scale by photograph graders who were masked to the clinical information. results of the subjects, 59 had dr. the prevalence of dr increased steeply between the ninth and the tenth deciles for both variables. the roc curve analysis showed overall glycemic thresholds for dr of 6.5 mmol/l (117 mg/dl) for fpg and 6.2% (44 mmol/mol) for hba1c. the sensitivities and specificities were 78.0% and 87.1% for fpg and 89.8% and 89.5% for hba1c, respectively. the areas under the roc curves indicated that hba1c was a stronger discriminator of retinopathy: the area under curve was 0.880 for fpg and 0.946 for hba1c p < 0.001). however, the thresholds for detecting dr for the two measures showed no significant differences after excluding individuals receiving anti-hyperglycemic medication. conclusions these findings suggest that the hba1c and fpg thresholds for detecting diabetes in the iranian population are lower than the current diagnostic criteria.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Glycemic and Hemoglobin A1c Thresholds for Diagnosing Diabetes Based on Prevalence of Retinopathy in an Iranian Population

BACKGROUND The use of glycemic thresholds for diabetes diagnosis is controversial. However, no information is available regarding glycemic and glycated hemoglobin (HbA1c) thresholds for detecting diabetic retinopathy (DR) in the Iranian population. OBJECTIVES The main purpose of the current investigation was to examine the association of fasting plasma glucose (FPG) and HbA1c levels with diab...

متن کامل

Glycemic Thresholds for Diabetes-Specific Retinopathy

OBJECTIVE To re-evaluate the relationship between glycemia and diabetic retinopathy. RESEARCH DESIGN AND METHODS We conducted a data-pooling analysis of nine studies from five countries with 44,623 participants aged 20-79 years with gradable retinal photographs. The relationship between diabetes-specific retinopathy (defined as moderate or more severe retinopathy) and three glycemic measures ...

متن کامل

Biological variation of hemoglobin A1c: consequences for diagnosing diabetes mellitus.

1. Lundberg GD. When to panic over abnormal values. Med Lab Obs 1970;4:47–54. 2. Lundberg GD. Critical (panic) value notification: an established laboratory policy (parameter). JAMA 1990;263:709. 3. Hortin GL, Csako G. Critical values, panic values, or alert values? J Clin Path 1998;109: 496 –7. 4. Piva E, Plebani M. From “panic” to “critical” values: which path toward harmonization? Clin Chem ...

متن کامل

Thresholds of various glycemic measures for diagnosing diabetes based on prevalence of retinopathy in community-dwelling Japanese subjects: the Hisayama Study

BACKGROUND There has been controversy over the diagnostic thresholds of hemoglobin A1c (HbA1c) for diabetes. In addition, no study has examined the thresholds of glycated albumin (GA) and 1,5-anhydroglucitol (1,5-AG) for diagnosing diabetes using the presence of diabetic retinopathy (DR). We examined the optimal thresholds of various glycemic measures for diagnosing diabetes based on the preval...

متن کامل

Optimal Hemoglobin A1c Levels for Screening of Diabetes and Prediabetes in the Japanese Population

The aim of this study was to evaluate the utility of hemoglobin A1c (HbA1c) to identify individuals with diabetes and prediabetes in the Japanese population. A total of 1372 individuals without known diabetes were selected for this study. A 75 g oral glucose tolerance test (OGTT) was used to diagnose diabetes and prediabetes. The ability of HbA1c to detect diabetes and prediabetes was investiga...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian red crescent medical journal

جلد ۱۸، شماره ۸، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023