X-Ray Measurement of Stress by Using Solid-State Semi-Conductor Detector.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Solid-State Detector for X-ray Computed Tomography

Solid-state detector has recently been used for x-ray Computed Tomography (CT) because it has high light conversion efficiency, quantum efficiency and compact size, compared with Xenon gas detector. In order to reduce radiation dose to the patient in medical x-ray CT, it should be needed to maximize the quantum efficiency and signal-tonoise ratio (SNR) of the detector. In this study, 16-channel...

متن کامل

MEASUREMENT OF DIAGNOSTIC X-RAY SPECTRA USING CdZnTe DETECTOR

INTRODUCTION We directly measured diagnostic X-ray photon spectra produced by a single-phase 2-pulse diagnostic X-ray unit driven at 50 to 100 kV and a few mA(1), a mammographic X-ray unit at 25 to 32 kV and 3 times of 80 mAs(2) and an X-ray computed tomography (CT) scanner at 120 kV and 3 mA(3) have been analyzed. Since detected spectra were distorted by the response of CdZnTe(CZT) detector an...

متن کامل

X-ray Stress Measurement of Nickel-base Single Crystal Superalloy Using Two-dimensional Detector

The stress in a single crystal of nickel-base superalloy with 72 % volume fraction of '-phase was measured by the X-ray method. The specimen whose surface normal was parallel to [001] direction was oscillated around -axis during recording of the X-ray diffraction pattern with a two-dimensional position sensitive proportional counter (PSPC). The stress was determined from the measured strain u...

متن کامل

Measurement of stereotactic beam data of 9 MV X-rays using diode detector

Background: Radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. The presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. Materials and Methods : Small circular fields w...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Society of Materials Science, Japan

سال: 1994

ISSN: 1880-7488,0514-5163

DOI: 10.2472/jsms.43.766