Wall Shear Stress Calorimetric Micro-Sensor Designed for Flow Separation Detection and Active Flow Control

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wall Shear Stress Calorimetric Micro-Sensor Designed for Flow Separation Detection and Active Flow Control

This paper presents an efficient and high-sensitive micro-sensor designed for wall shear stress measurement. The main technical application targeted is flow separation detection for closed-loop active flow control. The sensor is a temperature-resistance transducer operating on heat transfer. The device is micro-structured with three substrate-free wires presenting a high aspect ratio, and perio...

متن کامل

The Micro-Pillar Shear-Stress Sensor MPS3 for Turbulent Flow

Wall-shear stress results from the relative motion of a fluid over a body surface as a consequence of the no-slip condition of the fluid in the vicinity of the wall. To determine the two-dimensional wall-shear stress distribution is of utter importance in theoretical and applied turbulence research. In this article, characteristics of the Micro-Pillar Shear-Stress Sensor MPS(3), which has been ...

متن کامل

Characterizations and Correlations of Wall Shear Stress in Aneurysmal Flow.

Wall shear stress (WSS) is one of the most studied hemodynamic parameters, used in correlating blood flow to various diseases. The pulsatile nature of blood flow, along with the complex geometries of diseased arteries, produces complicated temporal and spatial WSS patterns. Moreover, WSS is a vector, which further complicates its quantification and interpretation. The goal of this study is to i...

متن کامل

Flow instability and wall shear stress variation in intracranial aneurysms.

We investigate the flow dynamics and oscillatory behaviour of wall shear stress (WSS) vectors in intracranial aneurysms using high resolution numerical simulations. We analyse three representative patient-specific internal carotid arteries laden with aneurysms of different characteristics: (i) a wide-necked saccular aneurysm, (ii) a narrower-necked saccular aneurysm, and (iii) a case with two a...

متن کامل

Development of Wall Shear Stress in Görtler Vortex Flow

The development of wall shear stress in Görtler vortex flow was investigated by hot-wire measurements. The wavelengths of the vortices were pre-set by thin vertical perturbation wires so to produce the most amplified wavelengths. Three different vortex wavelengths of 12 mm, 15 mm, and 20 mm were considered, and near-wall velocity measurements were carried out to obtain the “linear” layers of ve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Proceedings

سال: 2017

ISSN: 2504-3900

DOI: 10.3390/proceedings1040376