Hydrodynamics and mass transfer inthree-phase airlift reactors for activated Carbon and sludge filtration
A bioreactor refers to any manufactured or engineered device that supports a biologically active environment. These kinds of reactors are designed to treat wastewater treatment. Volumetric mass transfer coefficient and the effect of superficial gas velocity, as the most important operational factor on hydrodynamics, in three-phase airlift reactors are investigated in this study. The experiments...
متن کاملGas-Liquid Interfacial Area, Bubble Size and Liquid-Phase Mass Transfer Coefficient in a Three-Phase External Loop Airlift Bubble Column
The interfacial area a was measured by the sulfite oxidation method in a three-phase external loop airlift bubble column suspending completely the different concentrations of ion exchange resin particles in aqueous carboxymethyl cellulose (CMC) solutions with a wide range of viscosity. The column had been previously studied for the circulating liquid velocity UL, gas holdup G and volumetric gas...
متن کاملDetermination of Volumetric Mass Transfer Coefficient in Gas-Solid-Liquid Stirred Vessels Handling High Solids Concentrations: Experiment and Modeling
Rigorous analysis of the determinants of volumetric mass transfer coefficient (kLa) and its accurate forecasting are of vital importance for effectively designing and operating stirred reactors. Majority of the available literature is limited to systems with low solids concentration, while there has always been a need to investigate the gas-liquid hydrodynamics in tanks handling ...
متن کاملGas Hold-up Characteristics of an External Loop Airlift Contactor
Conventional airlift contactor (UT-ALC) was modified to improve its performance. The modified system (CDT-ALC) was tested for gas hold-up characteristics. Hydrodynamic environment depends on gas hold-up. New system reported 50 % higher gas hold-up. Linear relation between superficial gas velocity and fractional gas hold-up were developed from experimental data for both the reactors.
متن کاملThe Effects of Geometry and Operational Conditions on Gas Holdup, Liquid Circulation and Mass Transfer in an Airlift Reactor
In airlift reactors transport phenomena are achieved by pneumatic agitation and circulation occurs in a defined cyclic pattern through a loop. In the present work, the effect of geometrical relations on gas holdup and liquid velocity, and consequently on the gas-liquid mass transfer coefficient, was studied in a 6liter airlift bioreactor with AD/AR = 0.63; AD, downcomer cross-sectional area, an...