Voltage-Induced Sample Release from Anion Exchange Supports in Capillary Electrochromatography.
نویسندگان
چکیده
منابع مشابه
Monolithic columns with mixed modes of reversed-phase and anion-exchange stationary phase for capillary electrochromatography.
A capillary electrochromatography (CEC) monolithic column with mixed modes of reversed-phase and anion-exchange stationary phases was prepared by in situ polymerization of 2-(methacryloxy)ethyltrimethylammonium methyl sulfate (MEAMS) and ethylene dimethacrylate (EDMA) in a binary porogenic solvent consisting 1-propanol and 1,4-butanediol. The ammonium groups on the surface of the stationary pha...
متن کاملFundamentals of capillary electrochromatography: migration behavior of ionized sample components.
The mechanism of separating charged species by capillary electrochromatography (CEC) was modeled with the conditions of ideal/linear chromatography by using a simple random walk. The most novel aspect of the work rests with the assumption that in sufficiently high electric field ionized sample components can also migrate in the adsorbed state on the ionized surface of the stationary phase. This...
متن کاملVinylbenzyl quaternary ammonium-based polymeric monolith with hydrophilic interaction/strong anion exchange mixed-mode for pressurized capillary electrochromatography.
A novel polymeric monolith with hydrophilic interaction and strong anion-exchange mixed-mode has been fabricated for pressurized capillary electrochromatography by an in situ copolymerization of vinylbenzyl trimethylammonium chloride (VBTA) and bisphenol A glycerolate dimethacrylate (BisGMA). The optimization of the polymerization mixture composition has been investigated, and column characteri...
متن کاملGradient elution in capillary electrochromatography.
In analogy to pressure-driven gradient techniques in high-performance liquid chromatography, a system has been developed for delivering electroosmotically driven solvent gradients for capillary electrochromatography (CEC). Dynamic gradients with submicroliter per minute flow rates are generated by merging two electroosmotic flows that are regulated by computer-controlled voltages. These flows a...
متن کاملSemipreparative capillary electrochromatography.
Capillaries with inner diameters of 550 microm have successfully been packed with 1.5-microm octadecyl silica particles using frits made of macroporous polymers by the UV photopolymerization of a solution of glycidyl methacrylate and trimethylolpropane trimethacrylate. This type of frit is found superior to one made of low-melting point poly(styrene-co-divinylbenzene) beads. Bubble formation is...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 1998
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.14.571