Virtual bolus for total body irradiation treated with helical tomotherapy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Virtual bolus for total body irradiation treated with helical tomotherapy

Intensity-modulated radiation therapy (IMRT) for total body irradiation (TBI) is practiced in several centers using the TomoTherapy System. In this context the planning target volume (PTV) is the entire body including the skin. A safety margin in the air surrounding the body should be added to take into account setup errors. But using inverse planning, over-fluence peak could be generated in th...

متن کامل

Total Body Irradiation (TBI) using Helical Tomotherapy in children and young adults undergoing stem cell transplantation

BACKGROUND Establishing Total Body Irradiation (TBI) using Helical Tomotherapy (HT) to gain better control over dose distribution and homogeneity and to individually spare organs at risk. Because of their limited body length the technique seems especially eligible in juvenile patients. PATIENTS AND METHODS The cohort consisted of 10 patients, 6 female and 4 male, aged 4 - 22 y with acute lymp...

متن کامل

Craniospinal irradiation using helical tomotherapy for central nervous system tumors

The aim of this study was to describe early and late toxicity, survival and local control in 45 patients with primary brain tumors treated with helical tomotherapy craniospinal irradiation (HT-CSI). From 2006 to 2014, 45 patients with central nervous system malignancies were treated with HT-CSI. The most common tumors were medulloblastoma in 20 patients, ependymoma in 10 patients, intracranial ...

متن کامل

Helical Tomotherapy® is a Safe and Feasible Technique for Total Scalp Irradiation

Angiosarcoma of the scalp is a rare aggressive tumor that affects elderly patients. Chemoradiation is the treatment of choice for multicentric and extensive disease. The shape of the scalp represents a dosimetric challenge in terms of achieving a homogeneous concave dose distribution with coverage of the entire target volume and an acceptable organs-at-risk sparing. We report a case of an 81-ye...

متن کامل

Adequate target volume in total-body irradiation by intensity-modulated radiation therapy using helical tomotherapy: a simulation study

Recently, intensity-modulated radiation therapy (IMRT) has been used for total-body irradiation (TBI). Since the planning target volume (PTV) for TBI includes the surrounding air, a dose prescription to the PTV provides high fluence to the body surface. Thus with just a small set-up error, the body might be exposed to a high-fluence beam. This study aims to assess which target volume should be ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Clinical Medical Physics

سال: 2015

ISSN: 1526-9914

DOI: 10.1120/jacmp.v16i6.5580