Vibrational stability of a cryocooled horizontal double-crystal monochromator
نویسندگان
چکیده
منابع مشابه
Vibrational stability of a cryocooled horizontal double-crystal monochromator
The vibrational stability of a horizontally deflecting double-crystal monochromator (HDCM) is investigated. Inherently a HDCM will preserve the vertical beam stability better than a `normal' vertical double-crystal monochromator as the vibrations of a HDCM will almost exclusively affect the horizontal stability. Here both the relative pitch vibration between the first and second crystal and the...
متن کاملCharacterization of a bent Laue double-crystal beam-expanding monochromator
A bent Laue double-crystal monochromator system has been designed for vertically expanding the X-ray beam at the Canadian Light Source's BioMedical Imaging and Therapy beamlines. Expansion by a factor of 12 has been achieved without deteriorating the transverse coherence of the beam, allowing phase-based imaging techniques to be performed with high flux and a large field of view. However, preli...
متن کاملDevelopment of a bent Laue beam-expanding double-crystal monochromator for biomedical X-ray imaging
The Biomedical Imaging and Therapy (BMIT) beamline at the Canadian Light Source has produced some excellent biological imaging data. However, the disadvantage of a small vertical beam limits its usability in some applications. Micro-computed tomography (micro-CT) imaging requires multiple scans to produce a full projection, and certain dynamic imaging experiments are not possible. A larger vert...
متن کاملFeedback system of a liquid-nitrogen-cooled double-crystal monochromator: design and performances.
A new set-up is reported of an indirect cryogenic cooling system for a double-crystal monochromator which runs on the BM30b/FAME beamline at the ESRF (Grenoble, France). This device has been conceived to limit the vibrations on the first diffracting crystal and to maintain it at a constant temperature. These points are crucial for maximizing the beamline stability. Moreover, the relative angula...
متن کاملDesign of a new soft X-ray double crystal monochromator beamline, BL-13
A new soft X-ray double crystal monochromator beamline is designed and will be constructed at BL-13. Special care is paid for the degree of parallelism of the beam and the beam size at the focal point. We propose to use two toroidal mirrors, one for producing a parallel beam and another for focusing the beam at the sample position. Although a toroidal mirror is not ideal to produce a parallel b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Synchrotron Radiation
سال: 2016
ISSN: 1600-5775
DOI: 10.1107/s1600577516009243