Vibration Reduction of Power Transformer Core.
نویسندگان
چکیده
منابع مشابه
On the influence of core laminations upon power transformer noise
Power transformers can be sources of disturbing and annoying acoustic noise. This paper is a first phase report of a wider framework of study that investigates the noise radiation characteristics of air-cooled power transformers. The dynamics of the transformer core structure plays a significant role in the noise generation process. The reported work focuses on the influence of lamination of th...
متن کاملFlexible Power Electronic Transformer for Power Flow Control Applications
This paper proposes a Flexible Power Electronic Transformer (FPET) for the application in the micro-grids. The low frequency transformer is usually used at the Point of Common Coupling (PCC) to connect the low voltage grid and utility network to each other. The conventional 50Hz transformer results in enhanced low voltage-grid power management system during grid-connected operation. In this pap...
متن کاملTransformer Monitoring by using Vibration Analysis
Since power transformer is a complex and critical component of the power transmission and distribution system, their reliability is crucially important for the energy system operation. So, there is an increasing interest in applying monitoring systems and on line diagnosis methods to transformers, as these are one of the most expensive and critical apparatus of a power system. Detecting failure...
متن کاملCorrelation of Dga, Uhf Pd Measurement and Vibration Data for Power Transformer Monitoring
Reliability of electrical energy networks depends on quality and availability of electrical equipment like power transformers. Local failures inside their insulation may lead to catastrophic breakdowns. To prevent destroying events power transformers are e.g. tested on partial discharge (PD) activity. As testing is just snapshot information about transformers condition, permanent online monitor...
متن کاملStructure-vibration Analysis of a Power Transformer(154kV/60MVA/Single Phase)
The most common cause of power transformer failures is mechanical defect brought about by excessive vibration, which is formed by the combination of multiples of a frequency of 120 Hz. In this paper, the types of mechanical exciting forces applied to the power transformer were classified, and the mechanical damage mechanism of the power transformer was identified using the vibration transfer ro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
سال: 1993
ISSN: 0387-5024,1884-8354
DOI: 10.1299/kikaic.59.3694